Performance Table (Capacity In Gallons Per Minute) - Honda WSP33AA Operator's Manual

Submersible pump
Hide thumbs Also See for WSP33AA:
Table of Contents

Advertisement

Step 5. Plug in the pump and fill the sump basin with water. The pump should turn on
when the water level reaches 13'' to 14''. If it does not turn on at the 13'' to 14''
water level, remove the float cord from the clip and re-attach it in a higher or
lower position so that the pump turns on at the 13'' to 14'' water level.
Step 6. Perform several ON-OFF cycles to assure satisfactory operation.
Performance Table
Pump
WSP33K1AA
WSP53AA
WSP73AA
10
CLIP
MOVE
CORD
UP OR
DOWN
(Capacity in Gallons per Minute)
5
10
15
40
33
25
73
67
Total Head
20
25
30
35
15
60
51
40
27
74
67
58
49
FLOAT CORD
40
45
50
9
39
27
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wsp53aaWsp73aaWsp53Wsp33Wsp73Wsp33k1aa

Table of Contents