Step 5. Plug in the pump and fill the sump basin with water. The pump should turn on
when the water level reaches 13'' to 14''. If it does not turn on at the 13'' to 14''
water level, remove the float cord from the clip and re-attach it in a higher or
lower position so that the pump turns on at the 13'' to 14'' water level.
Step 6. Perform several ON-OFF cycles to assure satisfactory operation.
Performance Table
Pump
WSP33K1AA
WSP53AA
WSP73AA
10
CLIP
MOVE
CORD
UP OR
DOWN
(Capacity in Gallons per Minute)
5
10
15
40
33
25
73
67
Total Head
20
25
30
35
15
60
51
40
27
74
67
58
49
FLOAT CORD
40
45
50
9
39
27
16