  • Page 1 Owner’s Manual SUBMERSIBLE PUMP WSP50AA • WSP100AA © 2018 American Honda Motor Co., Inc.—All Rights Reserved...
  • Page 2 Thank you for purchasing this Honda Stainless Steel Sump Pump. We hope you are pleased with your purchase and that our pumps will provide you with long service life and exceptional performance. To ensure satisfactory service life, there are several considerations regarding proper installation, operation, and power source.
  • Page 3: Manufacturer And Pump Identification Data

    If the malfunction of the pump is not among those included in the troubleshooting table (see “14.2 TROUBLESHOOTING ” on page 10), contact the nearest authorized Honda pump dealer. 3. INTRODUCTION This publication contains all the necessary information and instructions for use and maintenance of your submersible sewage pump.
  • Page 4: Table Of Contents

    4. CONTENTS 1. MANUFACTURER AND PUMP IDENTIFICATION DATA... . .page 1 1.1 MANUFACTURER DATA ....... .page 1 1.2 PUMP DATA .
  • Page 5: General Safety Warnings

    5. GENERAL SAFETY WARNINGS FAILURE TO OBSERVE THESE WARNINGS AND/OR TAMPERING WITH THE PUMP RELIEVES THE MANUFACTURER OF ANY RESPONSIBILITY IN THE EVENT OF DAMAGE TO PERSONS OR OBJECTS AND/OR TO THE PUMP. Before starting the pump it is important for the user to know how to perform all the operations described in this manual and apply them at all times during maintenance of the pump.
  • Page 6: General Description

    6. GENERAL DESCRIPTION WSP50 and WSP100 series pumps are all similar from the functional and constructive point of view; the only differences are the following: • Power • Flow rate • Head • Weight • Dimensions WSP50 and WSP100 series pumps are used for handling water, even at high temperatures (see “7.1.
  • Page 7: Motor Technical Data

    7.2. MOTOR TECHNICAL DATA Power (Versions) 1/2 hp and 1 hp Poles Insulation class Degree of protection IP58 Type of duty continuous Phase-frequency-voltage 60Hz 115 volts single-phase Overload protection thermal protection single-phase Motor structure material molded steel Shaft material stainless steel Cable material SOW-NSO THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE...
  • Page 8: Non-Recommended Conditions Of Use

    8.2 NON-RECOMMENDED CONDITIONS OF USE WSP50 and WSP100 series pumps cannot be used for handling water containing acids and corrosive liquids in general, water with temperatures higher than 40°C, sea-water, or flammable and generally dangerous liquids. WSP50 and WSP100 pumps must never be allowed to run without water.
  • Page 9: Transport

    9.3 TRANSPORT The pump is packed in a cardboard box for transport; as its total weight and bulk are not excessive (fig.1) transport presents no problems . 10. INSTALLATION NOTICE TO LIFT OR LOWER THE PUMP, USE A ROPE FIXED TO THE HANDLE; NEVER USE THE ELECTRIC POWER CABLE.
  • Page 10: Assembly And Disassembly

    11. ASSEMBLY AND DISASSEMBLY The pump has no separate accessories, so no assembly is required for installation. If the pump has to be disassembled (due to breakage or any other reason), the user must notify their dealer or the manufacturer. FAILURE TO COMPLY WITH THIS RULE RENDERS THE DISTRIBUTOR’S LIMITED WARRANTY INVALID.
  • Page 11: Maintenance And Repairs

    14. MAINTENANCE AND REPAIRS 14.1 MAINTENANCE NOTICE Before performing any maintenance operations, disconnect the plug and/or switch off. THE PUMP MUST BE DISMANTLED ONLY BY THE DEALERSHIP TECHNICIANS. FAILURE TO OBSERVE THIS RULE RENDERS THE DISTRIBUTOR’S LIMITED WARRANTY INVALID. THE SAME APPLIES TO REPAIR JOBS AND/OR REPLACEMENTS.
  • Page 12: Troubleshooting

    The pump stops after brief periods of operation (tripping the thermal protection) CAUSE REMEDY Impeller blocked by Remove the foreign bodies; be certain to foreign bodies disconnect power Liquid temperature too The temperature exceeds the technical high limits of the pump Internal defect Contact the nearest Honda pump dealer...
  • Page 13: Illustrations

    15. ILLUSTRATIONS 15.1 INSTALLATION WITH MINIMUM FUNCTIONAL SPACES...
  • Page 14: Pump Impeller Cover Disassembly

    15.2 PUMP IMPELLER COVER DISASSEMBLY SOCKET HEAD SCREW (6) O-RING PUMP BODY...
  • Page 15: Wiring Diagram

    15.3 WIRING DIAGRAM Therm Prot Prot MOTOR Black Green Brown White Gray Yellow/Green...
  • Page 16: Warranty Service Information

    16. WARRANTY SERVICE INFORMATION Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership's management. The Service Manager or General Manager can help.
  • Page 17: Distributor's Limited Warranty

    What American Honda Will Repair or Replace Under Warranty: American Honda will repair or replace, at its option, any part that is proven to be defective in material or workmanship under normal use during the applicable warranty time period. Warranty repairs and replacements will be made without charge for parts or labor.
  • Page 18 Disclaimer of Consequential Damage and Limitation of Implied Warranties: American Honda disclaims any responsibility for loss of time or use of the product, transportation, commercial loss, or any other incidental or consequential damage. Any implied warranties are limited to the duration of this written limited warranty.
  • Page 19 Parts and accessories installed by a dealer who is authorized by American Honda to sell them will be repaired or replaced under warranty without charge for parts or labor. If installed by anyone else, parts and accessories will be repaired or replaced under warranty without charge for parts, but any labor charges will be the responsibility of the purchaser.
  • Page 20 NOTES...
  • Page 21 NOTES...
  • Page 22 NOTES...
  • Page 23 WSP50AA WSP100AA POM31WSP812 Printed on Recycled Paper MID.300.2018.09 Printed in U.S.A...

This manual is also suitable for:

Wsp100aa

Table of Contents