Honda WSP33AA Operator's Manual

Honda power equipment submersible pump
Hide thumbs Also See for WSP33AA:

Advertisement

Quick Links

OPERATOR'S MANUAL
SUBMERSIBLE PUMP
WSP33AA • WSP53AA • WSP73AA
BY:
©2003 American Honda Motor Co., Inc. — All Rights Reserved
© 2004 American Honda Motor Co., Inc. – All Rights Reserved

Advertisement

Table of Contents
loading

Summary of Contents for Honda WSP33AA

  • Page 1 OPERATOR'S MANUAL SUBMERSIBLE PUMP WSP33AA • WSP53AA • WSP73AA ©2003 American Honda Motor Co., Inc. — All Rights Reserved © 2004 American Honda Motor Co., Inc. – All Rights Reserved...
  • Page 2 Thank you for purchasing this Honda Stainless Steel Sump Pump. We hope you are pleased with your purchase and that our pumps will provide you with long service life and exceptional performance. To ensure satisfactory service life, there are several consid- erations regarding proper installation, operation and power source.
  • Page 3 Important Safeguards To reduce risk of injury, always follow these instructions and safety precautions when using this pump and to maintain warranty. Read All Instructions Prior to Installation (SAVE THESE INSTRUCTIONS) Installation/Operation: • Never lift or carry pump by the electrical cord. Use a chain or rope affixed on handle to install/remove pump.
  • Page 4 Important Safeguards Proper Lifting: A separate chain or rope should be attached to the handle for normal lifting. Please note that this will help prevent damage due to inadvertent lifting of the pump by the power cord. Rope attached to automatic pump for lifting and installation.
  • Page 5: Table Of Contents

    Contents Section Page General Application Information ....... . . 3 Safety Information and Introduction .
  • Page 6: General Application Information

    General Application Information (cont.) safety reasons. You should never touch a sump pump or discharge piping while the pump is connected to electrical power and water is present. The pump should be disconnected from the electrical source before handling in all cases. Discharge Piping Installation To assure the maximum performance from your sump pump, the discharge pipe size and piping fittings should not be smaller than the discharge port of the pump.
  • Page 7: Safety Information And Introduction

    General Application Information Basin and Cover The basin should not be less than 18 inches in diameter and 24 inches deep. Larger diameters are advisable in instances of increased pump capacity requirements: The basin should be located such that all water flows into the basin due to gravity. Outdoor installations should be at a sufficient depth to ensure protection from freezing.
  • Page 8: General Specifications

    • Knife or round file for smoothing inside of all plastic pipe connections Materials Needed • PVC or ABS pipe cement (read manufacturer’s instructions carefully) • PVC or ABS pipe; – 1 " for WSP33AA – 1 " for WSP53AA, WSP73AA • PVC adapter – 1 "...
  • Page 9: Installation Instructions

    Step 2: Attach desired length of PVC or ABS discharge pipe to pump outlet, using PVC adapter (1 " pipe and adapter for WSP33AA, 1 " WSP53AA, WSP73AA). Make sure open end of pipe will be above top of basin.
  • Page 10: Electrical Information

    Electrical information • Pumps are 115 V, 60 Hz and are grounded to prevent electrical shock. WARNING: Risk of electric shock—this pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding- type receptacle.
  • Page 11: Submersible Pump Installation

    PIPING Plastic PVC pipe is shown in the illustrations, but galvanized steel or copper pipe may be used if desired. All piping must be clean and free of all foreign matter to prevent clogging. Use thread compound on all threaded joints unless specified otherwise.
  • Page 12: Performance Table

    13'' to 14'' water level. MOVE CORD UP OR DOWN Step 6 – Perform several ON-OFF cycles to assure satisfactory operation. Performance Table TOTAL HEAD TOTAL HEAD ITEM NO WSP33AA WSP53AA WSP73AA CLIP (Capacity in Gallons per Minute) (cont.) FLOAT CORD...
  • Page 13: Installation Diagram

    WSP Submersible Pump Installation Diagram " check valve with rubber sleeve connectors *All equipment other than pump to be supplied by others. Pump only supplied by Honda. " Min. Bottom of inlet pipe 14" Min. Sump pump Grounded type 115 volt receptacle min.
  • Page 14: Motor Wiring Diagram

    Motor Wiring Diagram Automatic Operation Type Output (Single Phase) Operation Check the water level before starting the pump. If the pump is operated continuously for an extended period of time in a dry condition or at the lowest water level, the motor protector will be activated in single phase units.
  • Page 15: Technical Specifications

    Impeller Type Bearing Motor Single Phase Motor Protection Power Cord Automatic Float Switch * WSP33AA - Impeller/Diffuser is Thermo Plastic-Noryl GFN2 ** WSP33AA – HP Shaft Seal is Non-Mechanical Double Oil Seal (Rubber) Standard HP – 1 inch HP and HP –...
  • Page 16: Troubleshooting Checklist

    Troubleshooting Checklist PROBLEM Pump does not run or hums. Pump runs but does not deliver water. Pump runs and pumps out sump, but does not stop. Pump runs but delivers only a small amount of water. Fuse blows or circuit breaker trips when pump starts.
  • Page 17: Maintenance And Service

    Maintenance and Service WARNING: Pump warranty becomes void if you remove motor housing, unscrew impeller, or otherwise remove impeller seal. If pump does not operate properly, follow the steps shown under Troubleshooting. For any work on pump or switch, always unplug power cord(s). Do not just turn off circuit breaker or unscrew fuse.
  • Page 18: Sectional Views

    Sectional View – WSP33AA Automatic Type Output 1/3 HP (Single Phase) Recommended spare parts Ref. No. Outer Casing Suction Cover Impeller Sleeve Impeller Nut * 114 Oil Seal Lifting Hanger Strainer Float Switch Rotor Stator Capacitor Submersible Cable Motor Frame...
  • Page 19 Sectional View – WSP53AA, WSP73AA Automatic Type Output 1/2 to 3/4 HP (Single Phase) Recommended spare parts Ref. No. Outer casing Inner casing Seal cover Impeller Impeller nut *111-1 Mechanical seal *111-2 Mechanical seal Connection Band 304 Stainless Lifting hanger Strainer Float switch Rotor...
  • Page 20: Disassembly And Assembly

    Disassembly and Assembly Disassembly When disassembling pump, have a piece of cardboard or wooden board ready to place the different parts on as you work. Do not pile parts on top of each other. They should be laid out neatly in rows. The O-ring and gasket can not be used again once they are removed.
  • Page 21: Customer Service Information

    The Service Manager, General Manager, or Owner can help. Almost all problems are solved in this way. If you are dissatisfied with the decision made by the dealership's management, you may contact the Honda Power Equipment Customer Relations Office. You can write to: American Honda Motor Co., Inc.
  • Page 23 POM53680 2200.2005.04 P/N 31WSP602 Printed on PRINTED IN U.S.A. Recycled Paper...

This manual is also suitable for:

Wsp53aaWsp73aa

Table of Contents