Func.
Name
Code
PM
const
H112
inductance, Auto)
PM
const
H113
inductance, Auto)
H116
PM Speed Response
H117
PM Starting Current
H118
PM Starting Time
H119
PM Stabilization Constant
H121
PM Minimum Frequency
H122
PM No-Load Current
H123
PM Starting Method Select
PM Initial Magnet Position
H131
Estimation 0V Wait Times
PM Initial Magnet Position
H132
Estimation
Detect
Times
PM Initial Magnet Position
H133
Estimation Detect Times
PM Initial Magnet Position
H134
Estimation Voltage Gain
"H" Function
Description
0.01-655.35 [mH]
Ld(d-axis
0.01-655.35 [mH]
Lq(q-axis
1-1000 [%]
20.00-100.00 [%]
0.01-60.00 [s]
0-120 [%]
0.0-25.5 [%]
0.00-100.00 [%]
00... Normal
01... Initial Magnet Position
Estimation
0-255
0-255
Wait
0-255
0-200
80
Run
Defaults
Mode
Lnitial data
Units
Edit
kW
mH
dependent
kW
mH
dependent
%
100
%
70.00[%]
1.00[s]
%
100[%]
%
8.0 [%]
%
10.00 [%]
0
10
10
30
100
s
-
-
-
-
-