Hitachi WJ200 Series Quick Reference Manual page 58

Hide thumbs Also See for WJ200 Series:
Table of Contents

Advertisement

Func.
Name
Code
Acceleration curve constant
a131
Deceleration curve constant
a132
A input select for calculate
A141
function
B input select for calculate
A142
function
Calculation symbol
A143
ADD frequency
A145
ADD direction select
A146
Curvature of EL-S-curve at the
a150
start of acceleration
Curvature of EL-S-curve at the
a151
end of acceleration
Curvature of EL-S-curve at the
a152
start of deceleration
Curvature of EL-S-curve at the
a153
end of deceleration
Deceleration hold frequency
a154
Deceleration hold time
a155
"A" Function
Description
Range is 01 to 10.
Range is 01 to 10.
Seven options:
00...Operator
01...VR
02...Terminal [O] input
03...Terminal [OI] input
04...RS485
05...Option
07...Pulse train input
Seven options:
00...Operator
01...VR
02...Terminal [O] input
03...Terminal [OI] input
04...RS485
05...Option
07...Pulse train input
Calculates a value based on the
A input source (A141 selects) and
B input source (A142 selects).
Three options:
00...ADD (A input + B input)
01...SUB (A input - B input)
02...MUL (A input * B input)
An offset value that is applied to
the output frequency when the
[ADD] terminal is ON.
Range is 0.0 to 400.0 Hz
Two options:
00...Plus (adds A145 value to the
output frequency setting)
01...Minus (subtracts A145 value
from the output frequency
setting)
Range is 0 to 50%
Range is 0 to 50%
Range is 0 to 50%
Range is 0 to 50%
Sets the frequency to hold
deceleration, range is 0.0 to
400.0Hz
Sets the duration of deceleration
hold, range is 0.0 to 60.0
seconds
56
Run
Defaults
Mode
Lnitial data
Units
Edit
02
02
02
03
00
0.00
Hz
00
10.
%
10.
%
10.
%
10.
%
0.0
Hz
0.0
sec.

Advertisement

Table of Contents
loading

Table of Contents