Wiring And Terminal Description - Hitachi NE-S1 series Basic Manual

Hide thumbs Also See for NE-S1 series:
Table of Contents

Advertisement

4.2 Wiring and terminal description

ELB
Power source,
3-phase or
1-phase, per
inverter model
Refer to QRG (section 5.7) when using
external equipment for source logic
output and/or external power supply.
Intelligent inputs,
7 terminals
1kΩ~2kΩ
Note 1) Above shows an example of voltage (O) input. Changeover of SW6 must be done in case of current (OI) input. (Refer to page 9).
(1) Mains terminal description
Symbol
R/L1(L1)
Power input terminals
S/L2
T/L3(N)
U/T1
V/T2
Power output terminals
W/T3
PD/+1
DC link choke connection
terminal
P/+
G(
)
Earth terminal
MC
R/L1
S/L2
T/L3
Short circuit bar
P24
PLC
L
5
4.7kΩ
4
3
2
1
4.7kΩ
DC10V
H
(10mA Max.)
O/OI
0-10VDC(10bit)
SW6
Approx.
250Ω
FM
Pulse train output
L
Name
Connect power supply
- Use [L1] and [N] terminal in case of 1-ph. 200V power supply
Connect 3-ph. motor
First, remove the short circuit bar between PD/+1 and P/+ terminal.
Then connect optional DC link choke for improving the input harmonics.
To make grounding. Be sure to make this grounding to avoid electric shock, and for improving
the EMC performance. The terminal is located on the heatsink.
(L1)
(N N N N )
DC24V
L
DC10V
O O O O
OI
Approx.1
0kΩ
L
L
L
Category D grounding (200V class)
8
U/T1
V/T2
W/T3
Short circuit bar
PD/+1
DCL
Remove the jumper
wire when using DCL
(DC link choke)
P/+
AL0
AL1
Relay contacts
AL2
11
Intelligent input terminal
CM2
Description
M
Motor