LINE VO LTAGE ADJUSTMENT
The GOLDMUND GOLD CUBE amplifier is internally wired for a
specif ic line voltage.
ATTENTION : A 234V adjusted amplifier will function properly
f or AC line voltage between 2OOV and 245Y . For
a 1 1 7V version, the AC line must deliver between
105 and 125V. lf your AC line is usually out of
these tolerances, please consult your GOLDMUND
dealer.
Please check the value of the main line f use. This f use is located
on the bottom of the amolifier, near a corner.
The golden lid can be removed with a smallscrewdriver or better
with a coin, and then the f use holder.
Use a 3A slow-blow fuse for 22OV and a 5A slow-blow fuse for
1 1 0 V .
4 .
CON N EC T I ONS
Connectthe power cord of the amplifier in the nearest wall plug.
Use only a 3 lugs grounded plug, for safety reasons. To get the
best sound of the amplif ier, avoid any multiple plug or extension
cord.
Connect the interconnect between the preamp and the power
amp. The RCA female socket is the highest quality WBT socket
(ground connectsfirst and the plug may be locked if you use the
GOLDMUND-M lT interconnect).
lf the GOLD CUBE is used with an APOLOGUE, use the provided
bi-male iunctions to plug it inside the special lodging in the
speaker back. The proper position of the cube is when the power
cord and the power switch are visible on the bottom angle of the
cube from the outside.
Otherwise, connectthe speaker cables tothe two banana recep-
tacle located on the opposite face from the input. The " + " is
marked with a red dot.
The amplifier is non-inverting in phase.