Whirlpool Duet GEW9250PW Use & Care Manual page 7

Electronic electric dryer
Table of Contents

Advertisement

If using a power s upply cord:
Use a ULapproved power s upply c ordkitmarked foruse with
clothes d ryers. The kitshould contain:
• AULapproved 30amppower supply cord, r ated
120/240-volt minimum. The cordshould b etypeSRD or
SRDT a ndbeatleast 4 ft (1.22 m)long. T he wires t hat
connect tothedryer m ust e ndinringterminals orspade
terminals withupturned ends.
• AULapproved strain relief.
If your outlet looks like this:
4-wire receptacle
(14-30R)
Then choose a 4-wire power supply cord with ring or spade
terminals and UL approved strain relief. The 4-wire power supply
cord, at least 4 ft (1.22 m) long, must have 4, 10-gauge copper
wires and match a 4-wire receptacle of NEMA Type
14-30R. The ground wire (ground conductor) may be either green
or bare. The neutral conductor must be identified by a white
cover.
If your outlet looks like this:
GROUNDING
INSTRUCTIONS
m For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer uses a cord having an equipment-grounding
conductor and a grounding plug. The plug must be plugged
into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
m For a permanently connected dryer:
This dryer must be connected to a grounded metal,
permanent wiring system, or an equipment-grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding
terminal or lead on
the dryer.
WARNING:
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personne! if you are in doubt as to whether the dryer is
properly grounded. Do not modify the piug on the power
supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE
INSTRUCTIONS
3-wire receptacle
(10-30R)
Then choose a 3-wire power supply cord with ring or spade
terminals and UL approved strain relief. The 3-wire power
supply cord, at least 4 ft (1.22 m) long, must have 3, 10-gauge
copper wires and match a 3-wire receptacle of NEMA
Type 10-30R.
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
Flexible armored cable or nonmetallic
sheathed copper cable
(with ground wire), protected with flexible metallic conduit. All
current-carrying
wires must be insulated.
10-gauge copper wire (do not use aluminum).
At least 5 ft (1.52 m) long.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Duet gew9250plDuet gew9250pw0Duet gew9250pt0

Table of Contents