Change Hydraulic System Filter; Wheel Hub - Slotted Nut Torque Specification - Exmark LAZER Z XS Operator's Manual

Air-cooled models
Hide thumbs Also See for LAZER Z XS:
Table of Contents

Advertisement

Remove spark plugs, check condition and reset gaps,
or replace with new plugs. See Engine Owner's
Manual.
Change Fuel Filter
Service Interval: As required
A fuel filter is installed between the fuel tanks and the
engine. Replace when necessary.
Replacement Filters
Briggs & Stratton
Change Hydraulic System
Filter
Service Interval: After the first 250 hours
Every 500 hours/Yearly
(whichever comes
first) thereafter
(Every 250 hours/Yearly if
using Mobil 1 15W50)
Note: Use only Exmark Part No. 103-2146.
1. Stop engine, wait for all moving parts to stop, and
remove key. Engage parking brake.
2. Raise seat.
3. Carefully clean area around filter. It is important
that no dirt or contamination enter hydraulic
system.
4. Unscrew filter to remove and allow oil to drain
from reservoir.
Important: Before reinstalling new filter, fill
it with Exmark Premium Hydro oil and apply
a thin coat of oil on the surface of the rubber
seal.
Turn filter clockwise until rubber seal contacts the
filter adapter, then tighten the filter an additional
2/3 to 3/4 turn.
5. Fill reservoir as stated in Check Hydraulic Oil
Level section.
Exmark Premium Hydro Oil is recommended.
Refer to the chart for an acceptable alternative:
Briggs & Stratton P/N
695327
Hydro Oil
Exmark Premium Hydro
Oil (Preferred)
Mobil 1 15W50
6. Raise the rear of machine up and support with
jack stands (or equivalent support) just high
enough to allow drive wheels to turn freely.
7. Start engine and move throttle control ahead to
full throttle position. Move the speed control
levers to the full speed and run for several
minutes. Shut down machine and recheck oil
level.
Note: Do Not change hydraulic system oil (except
for what can be drained when changing filter), unless
it is felt the oil has been contaminated or been
extremely hot.
Changing oil unnecessarily could damage hydraulic
system by introducing contaminates into the system.
Wheel Hub - Slotted Nut
Torque Specification
Service Interval: After the first 100 hours
See Figure 15 to determine which slotted nut has
been installed on the unit.
1. Style A (black finish)
2. .03 inch (.76 mm)
• Style A (black finish):
Torque the slotted nut to 211-260 ft-lb (286-352
N-m).
Note: Do Not use anti-seize on wheel hub.
• Style B (yellow zinc):
1. Remove and discard the cotter pin.
35
Maintenance
Change Interval
500 Hours
250 Hours
Every 500 hours thereafter
Figure 15
3. Style B (yellow zinc)
4. .24 inch (6 mm)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents