Advertisement

Memory test

Use the BCU or the HCM to perform a memory test for the adapter.
NOTE
Performing the memory test disables the adapter.
Performing a memory test through BCU
Use the diag --memtest command to test the adapter's memory blocks.
diag --memtest <ad_id>
where:
ad_id
Performing a memory test through HCM
Use the Hardware Tests tab on the Diagnostics dialog box as follows to perform a memory test.
1. Launch the HCM.
2. Select Configure > Diagnostics.
3. Click the Hardware Tests tab.
4. Select Memory Test.
5. Specify the test cycle using a positive number.
6. Click Start.

Pinging Fibre Channel end points

Use the BCU and HCM to ping a Fibre Channel end point from an adapter port to determine the
basic connectivity to the remote port and monitor network latency.
NOTE
Ping testing is not supported on Solaris systems.
Issuing a ping command to end points through BCU
Use the fcdiag --fcping BCU command to test the connection to a Fibre Channel end point.
fcdiag -–fcping <port_id> <rpwwn> [-l <lpwwn>]
where:
port_id
rpwwn
lpwwn
Brocade Adapters Troubleshooting Guide
53-1002145-01
ID of the adapter.
ID of the adapter port from which you want to ping the remote port. This could
be the PWWN, port hardware path, or user-specified port name. This could
also be the adapter-index/port-index. For example, to specify adapter 1, port
1, you would use 1/1 as the port identification.
Remote PWWN that you want to ping.
Logical PWWN. 0 indicates the base port.
3
Diagnostics
93