Unitoperates b utTelemet-
ricHRnotdisplayed
Console d isplays
" E2" error
code
No speed/RPM reading,
Console displays "Please
Pedal" error code
Handlebars
Chest Strap (optional)
Interference
Replace Chest Strap
Replace Console
Check data cable integrity
Check data cable
connections/orientation
Console Electronics
Check data cable integrity
Check data cable
connections/orientation
Check magnet position
(requires shroud removal)
Check Speed Sensor (re-
quires shroud removal)
If tests reveal no other issues, Handle-
bars should be replaced.
Strap should be "POLAR _'' compat-
ible and uncoded. Make sure strap is
directly against skin and contact area
is wet.
Try moving unit away from sources of
interference (TV, Microwave, etc).
If interference is eliminated and HR
does not function, replace strap.
If HR still does not function, replace
Console.
All wires in cable should be intact. If any
are cut or crimped, replace cable.
Be sure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
_lace.
If tests reveal no other issues, Console
should be replaced.
All wires in cable should be intact. If any
are cut or crimped, replace cable.
Be sure cable is connected securely
and oriented properly. Small latch on
connector should line up and snap into
_lace.
Magnet should be in place on pulley.
Speed sensor should be aligned with
magnet and connected to data cable.
Realign sensor if necessary. Replace if
there is any damage to the sensor or
the connecting wire.