System
Specification
and Performance
Data Sheet
Refrigerator
Water
Filter Cartridge
Model
UKF8001AXX
Specifications
Service Flow Rate (Maximum) .............................................
0.78 GPM (2.9 L/rain)
Rated Service Life UKF8001AXX-750
(Maximum) ......750 gallons/2838
liters
Maximum
Operating
Temperature ..................................... 100° F/38 ° C
Minimum
Pressure Requirement ........................................ 35 psi/241
kPA
Minimum
Operating
Temperature ...................................... 33 ° F/1 ° C
Maximum
Operating
Pressure ............................................. 120 psi/827
kPA
PentaPure
1000 Apollo Road
Eagan, Minnesota
55121-2240
651.450.4913
EPA EST #35917-MN-1
Performance
Data
Parameter
Chlorine
T&O
Particulate _*
100834/B
USEPA
MCL
Standard No. 42: Aesthetic Effects
Influent
Challenge
Concentration
2.0 mg/L ± 10%
Min. Required
Reduction
50%
Influent
Average
1.88 mg/L
5,700,000
#/ml
Effluent
Average
Maximum
(0.05136364 mg/[
0.06
mg/L
30,583
#/nil
69,000
#/ml
% Reduction
Average
Minimum
>9726%
96.84%
99.52%
98.94%
at least
10,000
particles/ml
85%
Parameter
Turbidity
Cysts
Asbestos
Lead at pH 6.5
Lead at pH 8.5
Mercury
at pH 6.5
Mercury
at pH 8.5
Atrazine
Benzene
Carbofuran
1,4-Dichlolobenzene
Lindane
Texaphene
USEPA
MCL
1 NTU _*
99.5% Reduction
99% Reduction
0.015 mg/L
0.015 mg/L
0.002 mg/L
0.002 mg/L
0.003 mg/L
0.005 mg/L
0.04 mg/L
0.075 mg/L
0.0002 mg/L
0.003 mg/L
Standard No. 53: Health Effects
Influent
Challenge
Concentration
11 ± 1 NTU***
Minimum 5&OOO/L
107108fibers/L; fibers >10 nlicrometers in length
0.15 mg/L + 10%
0.15 mg/L + 10%
.006 mg/L ± 10%
.006 mg/L ± 10%
0.009 mg/L + 10%
0.015 mg/L ± 10%
0.08 mg/L ± 10%
.225 mg/L ± 10%
0.002 mg/L + 10%
0.015 ± 10O/o
Influent
Average
10.7 NTU
16&500 #/L
155 MF/L
0.153 mg/L
0.150 mg/L
0.006 mg/L
0.006 mg/L
0.009 mg/L
0.014 mg/L
0.081 mg/L
0.208 mg/L
0.002 mg/L
0.015 mg/L
Effluent
Average
Maximum
0.31 NTU
.049 NTU
<1 #/L
<1 #/L
<1 MF/L
<1 MF/L
<.001 mg/L
<.001 mg/L
<.OOl mg/L
<.001 mg/L
0.0003 mg/L
0.0005 mg/L
0.0008 mg/L
0.0015 mg/L
<0.002 mg/L
0.002 mg/L
0.0006 mg/L
0.0011 mg/L
<0.001 mg/L
<0.001 mg/L
<0.0005 mg/L
<0.0005 mg/L
0.0O0 mg/L
<0.0001 mg/L
<0.001 mg/L
<0.001 mg/L
% Reduction
Average
Minimum
9709%
95.20%
>99.99%
>99.99%
>99.99O/o
>99.99%
>99.35%
>9929%
>99.33%
>99.29%
95.70%
90.91%
86.22O/o
75.93o/o
76,99%
75.310/o
95.71%
92.14%
98.74%
98.46%
99.76%
99.74%
98.72%
96.50%
92.97O/o
91.67%
Min. Required
Reduction
0.5 NTU
>99.95%
99%
0.10 mg/L
0.10 mg/L
0.002 mg/L
0.002 mg/L
0.003 mg/L
0.005 mg/L
0.04 mg/L
0.075 mg/L
0.0002 mg/L
0.003 mg/L
* Tested
using
a flow
rate of 0.78 gpm;
pressure
of 60 psig;
pH of 75 + 0.5; temp.
of
68 ° + 5° F (20 ° + 3 ° C)
** Measurement
in Particles/mL
Particles
used were
0.5 - 1 microns
*** NTU - Nephelometric
Turbidity Units
Tested and certified by NSF International
against ANSI/NSF Standards 42 & 53
in models UKF8001AXX-750
for the reduction of:
Standard No. 42: Aesthetic Effects
Standard No. 53: Health Effects
Taste and Odo_ Reduction
Cbenlical Reduction Unit
Chlorine Taste & Odor
Lead, Atrazine, Lindane, Benzene,
Mechanical Filtration Unit
Carbofuran, 1,4-DichloTobenzene,
Particulate Reduction Class 1
Mercury & Toxaphene Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction
General Use Conditions
Read this Performance
Data Sheet and compare the
capabilities
of this unit with your actual water
treatment
needs.
DO NOT use this product where water is microbic-
logically unsafe or of unknown
quality without
adequate
disinfection
before or after the system.
System certified for cyst reduction
may be used on
disinfected
water that may contain filterable
cysts.
USE ONLY WITH COLD WATER SUPPLY. CHECK
FOR COMPLIANCE
WITH THE STATE AND LOCAL
LAWS AND REGULATIONS.
The PuriClean ®II retractable
water filtration
system
uses a UKF8001AXX
replacement
cartridge.
Timely
replacement
of filter cartridge
is essential for
performance
satisfaction
from this filtration
system.
Please refer to the applicable
section of your Use &
Care Guide for general operation,
maintenance
requirements
and troubleshooting.
This system has been tested according to ANSI/NSF
42
and 53 for reduction of the substance listed above. The
concentration
of the indicated substances
in water
entering the system was reduced to a concentration
less
than or equal to the permissible limit for water leaving
the system, as specified in ANSI/NSF
42 and 53.