Make Electrical Connection; Complete Installation - KitchenAid KXU4236YSS0 Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) range hood
Table of Contents

Advertisement

Available languages

Available languages

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect
power.
C
D
A. Home power supply cable
B. Black wires
C. UL fisted wire connectors
D. White wires
E. Green (or bare) ground wire from home power
supply connected
to green ground screw
F. Range hood power supply cable
2. Use UL listed wire connectors
and connect the black wires
(B) together.
3. Use UL listed wire connectors
and connect the white wires
(D) together.
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal
box.
Failure to do so can result in death, fire, or
electrical
shock.
4. Connect green (or bare) ground wire from home power supply
to the unused green ground screw (E) in the terminal box.
5. Install terminal box cover.
6. Reinstall the rear support.
7. Reinstall the 2 lateral supports.
8. Check that all light bulbs are secure in their sockets.
9. Reconnect power.
For Vented
Installations
Only:
Connect ventwork to hood. Seal joints with clamps to
make secure and airtight.
1. Replace grease filters. See the "Range Hood Care" section.
2. Check the operation of the range hood fan and light. See
"Range Hood Use" section.
If range hood does not operate, check to see whether a
circuit breaker has tripped or a household fuse has blown.
Disconnect
power and check wiring connections.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.