Prepare Location; Install Range Hood; Make Electrical Connection - KitchenAid KWCU380WSS0 Installation Instructions And Use & Care Manual

30" (76.2 cm), 36" (91.4 cm), 42" (106.7 cm)and 48" (121.9 cm) commercial style wall-mount canopy range hood
Hide thumbs Also See for KWCU380WSS0:
Table of Contents

Advertisement

Available languages

Available languages

Thehood attaches tothewall b yscrews d iscussed inthe
"Prepare Location" section.
1. Using 2ormore people, hang therange h ood onthetwo
mounting brackets and adjust themounting brackets from
inside thehood tomake thehood level.
IMPORTANT:
Make sure thattherange h ood issecurely
tightened against thewall.
2. Install the mounting screws i nto thewall u ntil t he screw heads
aretight. T he screws p rovided formounting thishood must
befastened intosolid wood. D onotfasten i ntosheet r ock
only.
3. Connect vent s ystem tohood. S eal alljoints withclamps.
4. Ifyourinstallation uses theoptional ductcover, fitthecover
flanges o ver t hebrackets. If installation uses thechimney
extension, fittheextension over t hebrackets. Install the
upper s ection f irst, t henfitthelower s ection o ver t heupper
section. Seal extension tohood withclamps.
;k,.9 1 R: _.. _¢.111
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
1. Disconnect
power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install a UL
listed or CSA approved V2"strain relief.
4.
Run 3 wires, black, white, green or bare, through strain relief
into terminal box. Use caulking to seal openings.
-q
A
...............
A. Home power supply cable
B. Black wires
C. UL fisted wire connectors
D. White wires
E.
F.
Green (or bare) ground wire from home
power supply connected
to green ground
screw
Range hood power supply cable
5. Use UL listed wire connectors
and connect black wires (B)
together.
6. Use UL listed wire connectors
and connect white wires (D)
together.
7. If optional heat lamp kit is used, connect black wires from
heat lamp with black wires from home power with UL listed
wire connectors.
Connect white wires from optional heat
lamp kit to home power with UL listed wire connectors.
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect
ground wire to green ground screw in
terminal
box.
Failure to do so can result in death, fire, or
electrical
shock.
8. Connect green (or bare) ground wire from home power supply
to the unused green ground screw (E) in the terminal box.
9. Tighten strain relief screws.
10. Install terminal box cover.
11. Check all light bulbs to make sure they are secure in their
sockets.
12. Reconnect power.
10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kwcu360wss0Kwcu300wss0Kwcu320wss0

Table of Contents