e)
Check that the blades are disengaged.
f)
Check that the spark plug wires are properly connected.
g)
Check for loose or faulty wiring connections.
h)
Check for corrosion at all wiring connections. Even minor corrosion may
cause a faulty connection. Clean connector terminals thoroughly with
electrical contact cleaner, apply dielectric grease and reconnect.
NOTE: When disconnecting electrical connectors DO NOT pull on the
wires to separate the connectors.
NOTE: After carefully checking the above steps, attempt to start the
engine. If it does not start, contact your authorized Exmark service
dealer.
IMPORTANT: It is essential that all operator safety mechanisms be
connected and in proper operating condition prior to mower use.
When a problem occurs, do not overlook the simple causes. For example,
starting problems could be caused by an empty fuel tank. The following table
lists some of the common causes of trouble. Do not attempt to service or
replace major items or any items that call for special timing of adjustments
procedures (such as valves, governor, etc.). Have this work done by
your Engine Service Dealer.
ENGINE TROUBLESHOOTING TABLE
NO
PROBLEM
FUEL
X
Will not start
X
Hard starting
X
Stops suddenly
Lacks power
Operates
erratically
Knocks or pings
Skips or misfires
Backfires
Overheats
High fuel
consumption
IMPROPER
DIRT IN
DIRTY AIR
FUEL
FUEL LINE
FILTER
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
- 34 -
FAULTY
BLOCKED
ENGINE
SPARK
FUEL
OVERLOADED
PLUG
FILTER
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
INCORRECT
DIRTY
OIL
AIR
LEVEL
SCREEN
X
X
X
X
X
X
X
X
X
X
X