Venting Requirements - Kenmore 110.98752 Use And Care Manual

24" wide (61 cm) laundry center washer - gas dryer
Table of Contents

Advertisement

Available languages

Available languages

Gas Supply Pressure Testing
The laundry center must be disconnected
from the gas
supply piping system during pressure testing at pressures
greater than 1/2psi.
Fire Hazard
Use a heavy meta_ vent.
Do not use a ptastic vent.
Do not use a meta_ foi_ vent.
Failure to follow
these instructions
can result in death
or fire.
WARNING;
To reduce the risk of fire, this laundry center
MUST BE EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, or a concealed space of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.
If this is a new vent system
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE TMventing products are recommended.
4" (10.2cm) heavy metal exhaust vent
TM
DURASAFE
vent products can be purchased from your
dealer. For further information, please call
1-800-4-MY-HOME
®(1-800-469-4663}
or visit our website at
www.sears.com.
Rigid metal vent
For best drying performance,
rigid metal vents are
recommended.
Rigid metal vent is recommended
to avoid crushing and
kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for
cleaning.
Flexible metal vent must be fully extended and supported
when the laundry center is in its final position.
Remove excess flexible metal vent to avoid sagging and
kinking that may result in reduced airflow and poor
performance.
Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Elbows
45° elbows provide better airflow than 90° elbows.
Good
Better
Clamps
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into the interior of the
duct. Do not use duct tape.
Clamp
Exhaust
Recommended hood styles are shown here.
B
(10.2
cm)
A. Louvered hood style
B. Box hood style
The angled hood style (shown here) is acceptable.
4"
(10.2 c_(f"_