WATER IS TOO HOT
1. Temperature
Selection
too high
Turn the temperature
adjustment
knob counter-clockwise
(to the left) to lower the maximum water temperature.
Note: This will increase
the activation
flow rate.
2. Inlet water temperature is very warm (60°-75°F)
Reduce inlet gas supply to lower the heaters degree rise.
Note: Only the Model 125BS should be used if the inlet
water is preheated.
NOTE: Only the model 125B LPS or 125B NGS should be
used if the inlet water is preheated.
3. Inlet filter screen is clogged, restricting flow
Remove screen and clean it.
WATER IS NOT HOT ENOUGH
1. Temperature selection is settoo low.
Change the setting. Turn the temperature selector knob
clockwise
(to the right). Note: this will decrease
the
activation flow rate.
2. Gas pressure
is insufficient
It is extremely
important
for a tankless
instantaneous
water
heater to have the right
size gas line to obtain
the
correct
gas pressure.
See specifications
on page 2. Unlike
storage tank water heaters, the burners of a tankless
water
heater must be very powerful
to heat water instantaneously
since they do this only at the time hot water
is actually
being used.
It is therefore _erative
that the gas pressure
requirement
be met exactly. Insufficient
gas pressure
will
directly
affect the water temperature
at the time of usage.
See page 2 for correct
gas pressure
settings and see page
11 for proper gas line sizing.
3. Gas supply
is insufficient
Make sure your main gas line is fully opened.
If using LP
gas, be sure that the size of the propane tank is adequate
to
supply the required gas pressure.
See gas pipe sizing chart
on page 11.
4. Cold water is mixing with the hot water between
the
AquaStar
and the outlet
Compare water temperature
at outlet of the AquaStar
(hold
the AquaStar's
outlet pipe with your hand)
and at the tap.
If these two are very different,
check for mixing valve or
plumbing
crossover
(see "NO
SPARK
AT THE PILOT"
paragraph
4). Where
automatic
"anti-scald"
valves are
required
by code,
lower the temperature
setting
on the
AquaStar
as much as possible
and balance
the pressure
between
cold and hot water after the AquaStar.
5. Parts in water valve are dirty or damaged,
which will
prevent
the gas valve from being fully opened.
If the internal
water
valve parts are damaged
from water
quality or use, or there is evident corrosion
where the water
valve and gas valve connect,
then
immediate
service
is
needed. See step 9 under the problem NO SPARK AT THE
PI LOT. White vinegar should be applied first to any corrosion
before the loosening
of screws.
HOT WATER TEMPERATURE
FLUCTUATES
/ UNIT
DEACTIVATED
1. Unbalanced
pressure
in waterlines
The added
restriction
caused
by the Aquastar
in the hot
water system can result in uneven pressures
between
the
cold and the hot. In such cases when mixing cold water at
the tap, the lower hot water pressure may be overpowered
by a much higher cold water pressure, which may cause the
Aquastar burners to shut down (deactivate). Make sure faucet
aerators or shower heads are free of minerals.
Do not add any flow restrictor
to the shower head.
Typically
this deactivation
symptom
is a result of the hot
water
being too hot to use comfortably.
Warm inlet water
generally
causes
this. Lowering
the control
knob setting
and/or
reducing
the inlet gas supply
to the heater should
correct
this deactivation
symptom.
2. Temperature
balance valves
If the inlet water
temperature
to the water
heater is very
warm the heater can produce
temperatures
that may be
found to be too hot. A temperature
balance shower
valve
can automatically
mix in cold water to reduce such hot water
temperature,
in the event of any temperature
instability with
the use of a temperature
balance
shower
valve, refer to
shower
valve
manufactures
instructions
for
internal
adjustment
setting.
Adjustments
should
be made to the
hottest
setting
in the shower
valve.
Additionally
the
temperature
control of the heater can be adjusted to produce
a more comfortable
hot water temperature.
See SETTING THE WATER TEMPE RATU RE section.
3. Cold water is mixing with the hot water between the
AquaStar and the outlet
See #4 under "NO SPARK AT THE PILOT".
4. Inlet water pressure
is erratic due to inadequate
supply
water
pressure
or saturated
pressure
tank
on well
system
Check the inlet water pressure.
For installation on a private
well system
with the use of a pressure
tank, the lowest
pressure
range setting
recommended
is 30-50
psi (2.07-
3.45 bar). Confirm that the pressure tank is not water logged.
5. Gas pressure
is too low
See page 2 for correct
specifications.
EXHAUST
FAN DOES NOT OPERATE
1. Check the fuse (see fig 9)
2. Check all electrical connections
3. Check adjustment of microswitch
(see Fig. 14)
FAN CIRCULATES
WHEN
HOT WATER IS SHUT
OFF
1. Check adjustment of microswitch
(see Fig. 14)
FAN OPERATES
WITHOUT
WATER FLOW
1. Unplug
the heater
and first
check
that
all electrical
and
electronic
connections
in the heater
are clean
and tight.
2. Check
adjustment
of microswitch
(see Fig. 14).
3. Control
box may need to be replaced
(see Fig 9). Check wire
connections
and test operation
of control
box (see Fig 9).