INSTANTANEOUS TYPE WATER HEATER FOR USE WITH NATURAL AND LIQUEFIED PETROLEUM GAS MODEL 125FX LP and 125FX NG Intended for variable flow applications with steady cold water inlet temperatures. For preheated domestic hot water, install the 125 BS model. For recirculating applications, install the 125 BL model.
Page 2
AQ125FXNG AQ125FXLPG max. 130 000 Btu/hr 125 000 Btu/hr Gas input min. 28 000 Btu/hr 28 000 Btu/hr...
FRONT VIEW SIDE VIEW MINIMUM INSTALLATION CLEARANCES FROM COMBUSTIBLE AND NON COMBUSTIBLE MATERIALS FOR ALCOVE OR CLOSET INSTALLATIONS MODEL 125FX TOP (A) 12" FRONT (B) 4" BACK 0" SIDES 4" FLOOR (C) 12" * FLUE DIAMETER 4" AQUASTAR MODEL 125FX...
Page 4
National Electrical Code CSA 22.1 Electrical Code.
Page 8
VENT HOOD MUST BE MOUNTED ONE FOOT MINIMUM ABOVE DOORS AND WINDOWS VENT HOOD MUST BE MOUNTED FOUR FEET AWAY FROM DOORS AND WINDOWS VENT HOOD VENT HOOD MUST BE MOUNTED FOUR FEET MINIMUM BELOW WINDOWS...
Page 10
Altitude Natural Gas Liquid Propane inches W.C: inches W.C: 0’ - 2.000 ft 5.38 2.000 ft - 4.500 ft 4.40 7.90 Fig. 7 - Water valve and S bend water connectors - top view...
Page 11
THREADED ASSEMBLY SWEATED ASSEMBLY 1/2 ELBOW 1/2 ELBOW S FITTING S FITTING Pressure Pressure Relief Relief PIPE PRV TO PIPE PRV TO Valve Valve APPROPRIATE APPROPRIATE DISCHARGE DISCHARGE 1 - microswitch 9 - ionization probe (flame 2 - electric control box sensor) 3 - exhaust fan 10 - pilot electrode...
Page 12
To operate the heater, set the ON/OFF switch to position I. The switch is located behind the flip down cover plate on the front panel strip. To shut down the gas to the heater, set the ON/OFF switch to position 0 Temperature Adjustment Knob Decrease Increases temperature...
Page 14
PILOT ORIFICE The AquaStar 125FX pilot and burners are ignited by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flow volume to activate the burners at its minimum flow requirement; Dirt in the water flow valve causing it to malfunction;...
Page 15
Do not add any flow restrictor to the shower head.
Do not add any flow restrictor to the shower head. WATER IS NOT HOT ENOUGH EXHAUST FAN DOES NOT OPERATE FAN CIRCULATES WHEN HOT WATER IS SHUT HOT WATER TEMPERATURE FLUCTUATES...
Page 17
Power cord Heat exchanger on/off switch Pilot assembly Temperature adjustment selector Burner manifold gas Microswitch pressure test nipple Gas inlet gas pressure test nipple Main gas burner Electric box Pilot gas tubing Exhaust Fan Gas valve Electronic control box...
Page 20
Replacement Parts available from North American Distributor...