Aquastar automatic instantaneous type water heaters for use with natural and liquefied petroleum gas installation and operating instructions 125b lps, 125b ngs (24 pages)
Bosch automatic instantaneous type water heaters for use with natural and liquefied petroleum gas (flow modulated with electronic ignition) suitable for heating potable water only not approved for space heating purposes (16 pages)
Page 1
All manuals and user guides at all-guides.com INSTALLATION AND OPERATING INSTRUCTIONS FOR AUTOMATIC INSTANTANEOUS TYPE WATER HEATERS FOR USE WITH NATURAL AND LIQUEFIED PETROLEUM GAS MODEL 125B LP and 125B NG (Flow Modulated) Suitable for heating potable water only Not approved for space heating purposes WARNING FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS...
Page 2
All manuals and user guides at all-guides.com FEATURES UNPACKING THE AQUASTAR HEATER...
Page 3
All manuals and user guides at all-guides.com MINIMUM INSTALLATION CLEARANCES FROM COMBUSTIBLE AND NON COMBUSTIBLE MATERIALS FOR ALCOVE OR CLOSET INSTALLATIONS MODEL 125B / 125B LOW PRESSURE / 125B SOLAR / 125X TOP (A) 12" FRONT (B) 4" BACK 0" SIDES 4"...
All manuals and user guides at all-guides.com COMBUSTION AIR REQUIREMENTS CLEARANCES MOUNTING INSTALLATION...
Page 6
All manuals and user guides at all-guides.com Before installing the unit, be certain you have the correct heater for your type of Gas Propane or Natural Gas. Identification labels are found on the shipping box, and on the rating plate which is located on the right side panel of VENTING...
Page 7
All manuals and user guides at all-guides.com Altitude Natural Gas Liquid Propane inches W.C: inches W.C: 0’ - 2.000 ft 5.7" 10.5" 2.000 ft - 4.500 ft 4.6" 8.4" GAS LINE SIZING GAS CONNECTIONS and Gas Regulator...
All manuals and user guides at all-guides.com WATER CONNECTIONS FOR YOUR SAFETY READ BEFORE LIGHTING THE PILOT SWEATED ASSEMBLY THREADED ASSEMBLY 1/2 ELBOW 1/2 ELBOW S FITTING S FITTING S FITTING PIPE PRV TO PIPE PRV TO APPROPRIATE APPROPRIATE DISCHARGE DISCHARGE...
All manuals and user guides at all-guides.com TROUBLE SHOOTING The AquaStar 125 burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flow volume to activate the burners at its minimum flow requirement;...
Page 11
All manuals and user guides at all-guides.com...
Page 12
All manuals and user guides at all-guides.com It is extremely important for a tankless instantaneous water heater to have the right size gas line to obtain the correct gas pressure Any sign of moisture or corrosion at the joint of the water valve and the gas valve is a sign that the water valve assembly components need to be replaced immediately Do not...
Page 13
All manuals and user guides at all-guides.com Diagram of AquaStar 125 B...
All manuals and user guides at all-guides.com INSTALLATION CHECKLIST GAS LINE SIZE Natural Gas Nominal Iron Pipe Size* 1/2" 3/4" 1" 10’ 40’ 150’ MAXIMUM LENGTH Liquid Propane Semi-rigid Tubing 1/2" 5/8" 3/4" 7/8" 20’ 60’ 150’ MAXIMUM LENGTH RECOMMENDED * Flex tubing greatly reduces capacity and, therefore, is not recommended.