Lroubleshooting -" - Guide; Start Up Conditions; Thermal Expansion; Strange Sounds - Kenmore 153.320491 HT Owner's Manual

Potable water heating only not suitable for space heating 30, 40, 50, 66, 82 gal.
Table of Contents

Advertisement

Troubleshooting
Guide
Start Up Conditions
THERMAL
EXPANSION
Water supply systems may, because of such events as high line
pressure, f_equent cut-offs, the effects of water hemmer among
others, have installed devices such as pressure reducing valves,
check valves, back flow preventers, etc._to control these types of
problems. When these devices are not equipped with an internal
by-pass, and no other measures are taken, the devices cause the
water system to be closed. As water is heated, it expands (ther-
mal expansion) and closed systems do not allow for the expan-
sion of heated water.
The water within the water heater tank expands as it is heated and
increases the pressure of the water system. If the relieving point of
the water heater s temperature-pressure relief valve is reached, the
valve will relieve the excesspressure. The temperature-pressure
relief valve is not intendedfor
the constant relief of thermal
expansion. This is an unacceptable condition and must be cor-
rected.
It is recommended that any devices installed which could create a
closed system have a by-pass and/or the system have an expan-
sion tank to relieve the pressure built by thermal expansion.
Thermal expansion tanks are available from Sears stores and
through the Sears Service Centers. Contact the local plumbing
inspector, water supplier and/or the Sears Service Center for
assistance in controlhng these situations.
Thermal
Expansion Tank Specifications
Model
Tank Capacity Dimensions in Inches
Pipe Fitting
Number
In Gallons
Diameter
Length
On Tank
153.331020
2
8 inches
12_ inches
_" Male
153.331050
5
11 inches 14_ inches
_" Male
HOT
COLD
WATER HEATER
COLD WATER
hINLET FITTING
WATER HEATER
COLD WATER
INLET Fn-rlNG
HOT
COLD
o)
PRESSURE
REDUCING
VALVE WITH
BY-PASS
(I)
EXPANSION
PRESSUREGAUGE
WATER
SHUTOFF
RECOMMENDED INSTALLATION
(VERTICAL MOUNTING)
FLOOR, CEIUNG
joist, ETC.
s'InRAPPING
O)
EXPANSION
O)
PRESSURE
REDUCING
INLET COLD
VALVE WTrH
WATER
BY-PASS
SHUTOFF
Expansion
Tank
Sizing
Chart
Water Heater Capacity (Gallons)
Inlet*
Water
Pressure
40psi
50psi
60psi
70psi
80psi
Expansion
30
40
50
66
82
Tank
2
2
2
5
5
Capacity
2
2
2
5
5
Needed
2
2
5
5
5
2
2
5
5
5
2
5
5
5
5
*Highest recorded inlet water pressure in a 24 hour period or
regulated water pressure.
NOTE:
Expansion tanks are pre-charged with a 40 psi air
charge. If the inlet water pressure is higher than 40 psi, the
expansion tank's air pressure must be adjusted to match that
pressure, but must not be higher than 80 psi.
(2)
pRESSURE GAUGE
ALTERNATE RECOMMENDED
INSTALLATION
(HORIZONTAL MOUNTING)
STRANGE
SOUNDS
Possible noises due to expansion and contraction of some metal
parts during periods of heat-up and cool-down do not represent
harmful or dangerous conditions.
21