If you choose to use the Dehumid function. This will remove excess moisture
from the air on excessively humid days.
Tr: temperature inside the room.
Ts:the set temperature.
1) When Tr>Ts÷3°F, t he compressor will run continuously the fan at the
selected speed.
2)When Ts-1°F<Tr<Ts+3°F the compressor will cycle for 10 minutes on
and 6 minutes off_
3)When Tr<Ts-1 °F,the compressor will shut off.
The dehumidification process takes place between the set temperature -1
and 3°F above the set temperature. (See Fig. # 5)
Fig. # 5
Control Panel.
For cool days you may want to run the "Fan Only" function. Here the fan
runs only at one of 2 speeds, Med. or Lo. The fan will not run at the High
speed. (See Fig. # 6)
Fig. # 6
Control Panel.