Download Print this page

GE GSW25LSTESS Owner's Manual And Installation page 28

Models 21, 23, 25, 27 and 29

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Installation
Instructions
INSTALLING THE WATER LINE
BEFORE YOU BEGIN
The water
line installation
is not warranted
bv the
refligerator
or icemaker
manufacturer.
Follow
these
recommendations
careflfllv
to minimize
the risk of
expensive
water
damage.
_'ater
hammer
(water
banging
in the pipes)
in house
i)lmnbing
can cause
damage
to refl'igerator
parts
and
lead
to water leakage
or flooding.
Call a qualified
plmnber
to correct
water hammer
betore
installing
the water sui)ply
line to the refl'igerator.
To prevent
burns
and product
damage,
do not hook
up the water
line to the hot water
line.
If wm use wmr refl'igerator
before
connecting
tile
water line, inake
sure the icelnaker
power
switch
is
in the 0 (off)
position.
Do not install
the icemaker
tubing
in areas
where
temi)eratures
tall below
fl'eezing.
When
using
any electrical
device
(such
as a power
drill)
during
installation,
be sure
the device
is
insulated
or wired
in a maimer
to i)revent
the hazard
of electric
shock.
All installations
must
be in accordm_ce
with
local
plmnbhlg
code
requirements.
Installation
of the icemaker
must
be done by a
qualified
service
tech_ficim_.
a, WARNING!
Connect
to potable
water sui)plv
only.
[] CONNECT
THE TUBING
TO THE
REFRIGERATOR
NOTES:
• Before
making
tile connection
to tile refl'igerator,
be sure tile refl'igerator
power
cord is not
plugged
into
the wall outlet.
• We recommend
installing
a water
filter ifwmr
water
SUl)ply has sand or particles
that could
clog
the screen
of the refrigerator's
water wove. Install
it in tile water line near
tile refl'igerator.
[]
CONNECT
THE TUBING TO THE
REFRIGERATOR
(CONT.)
Some
models
hm e file refl'igerator
comlection
at the end
of tubing
located
outside
the compressor
compartment
access
cover,
On other
models,
the
COllll)I'essor
COml)artment
access
coveF IlltlSt be rellloved
in order
to access
the refi'igemtor
c(mnection
at the
water
valve,
On
models
using
the
refl'igeration
connection
at
the
water
valve,
remove
the
plastic
flexible
cap,
©
Place the compression
nut and tbrmle
(sleexe)
onto the
end of the tubing
as shown,
Insert
the
end
of the
tubing
into
the water
xalxe
connection
as tier as possible.
While
holding
the
tubing,
tighten
the fitting,
Fasten
the
tubing
into
the clamp
proxided
to hold
it in a
vertical
position,
_%u ma} need
to i)i) open
the clamp,
One
of the
illustrations
below
will look
like the
connection
on your
icemaker,
Clam
Typical
Compression
Nut
Ferrule
Tubing
Typical
Compression N ut
Ferrule
(sleeve)
Refrigerator
onnection
Tubing
Refrigerator
Reattach
the access coxec
28

Advertisement

loading