Omron CPU Unit CJ2 Manual page 31

Programmable automation controllers
Hide thumbs Also See for CPU Unit CJ2:
Table of Contents

Advertisement

Ordering Information
Special I/O Units and CPU Bus Units
Process I/O Units
Isolated-type Units with Universal Inputs
Signal
Product
Input
range
name
points
selection
Set
4
separately
inputs
for each
input
Process
Input
Units
(Isolated-
type
Units
CJ
with
Special
Universal
I/O
Inputs)
Units
Set
4
separately
inputs
for each
input
Note: L and −100°C or less for K and T are ±2°C±1 digit max., and 200°C or less for R and S is ±3°C±1 digit max. No accuracy is specified for 400°C or less for B.
Isolated-type Thermocouple Input Units
Signal
Product
Input
range
name
points
selection
Process
2
Input
inputs
Units
(Isolated-
type
Thermo-
CJ
Set
couple
Special
separately
4
Input
I/O
for each
inputs
Units)
Units
input
Note 1. The accuracy depends on the sensors used and the measurement temperatures. For details, refer to the user's manual.
2. This is for an external power supply, and not for internal current consumption.
3. L and −100°C or less for K and T are ±2°C±1 digit max., and 200°C or less for R and S is ±3°C±1 digit max. No accuracy is specified for 400°C or less for B.
Conversion
Signal range
speed
temperature of
(resolution)
Universal inputs:
Pt100 (3-wire),
Resolution
JPt100 (3-wire),
(conversion
Pt1000 (3-wire),
speed):
Pt100 (4-wire), K,
1/256,000
J, T, E, L, U, N, R,
(conversion
S, B, WRe5-26, PL
cycle: 60 ms/
II, 4 to 20 mA, 0 to
4 inputs)
Standard
20 mA, 1 to 5 V,
1/64,000
accuracy: ±0.05%
0 to 1.25 V, 0 to 5
(conversion
of F.S.
V, 0 to 10 V, ±100
cycle: 10 ms/
mV selectable
4 inputs)
range −1.25 to
1/16,000
1.25 V, −5 to 5 V,
(conversion
−10 to 10 V, ±10 V
cycle: 5 ms/
selectable range,
4 inputs)
potentiometer
Accuracy:
Platinum
resistance
thermometer
input: (±0.3% of
Universal inputs:
PV or ±0.8°C,
Pt100, JPt100,
whichever is
Pt1000, K, J, T,
Conversion
larger) ±1 digit
L. R, S, B, 4 to
speed:
max.
20 mA,
250 ms/
Thermocouple
0 to 20 mA, 1 to
4 inputs
input: ±0.3% of
5 V, 0 to 5 V, 0 to
PV or ±1.5°C,
10 V
whichever is
larger) ±1 digit
max. (See note.)
Voltage or current
input: ±0.3% of
F.S. ±1 digit max.
Conversion
Signal range
speed
temperature
(resolution)
Thermocouple:
Conversion
Standard
B, E, J, K, L, N, R,
speed:
accuracy:
S, T, U, WRe5-26,
10 ms/
±0.05% of F.S.
PLII
2 inputs,
(See note 1.)
DC voltage:
Resolution:
±100 mV
1/64,000
Thermocouple:
Conversion
Accuracy:
R, S, K, J, T, L, B
speed:
(±0.3% of PV or
250 ms/
±1°C,
4 inputs
whichever
is larger) ±1
digit max.
(See note 3.)
Accuracy
No. of
(at ambient
External
unit
connection
numbers
25°C)
allocated
Removable
terminal
1
block
Accuracy
No. of
(at ambient
External
unit
connection
numbers
of 25°C)
allocated
Removable
terminal
1
block
Current
consumption
(A)
Model
Standards
5 V
24 V
0.30
CJ1W-PH41U
UCI, CE
.032
CJ1W-AD04U
UCI, CE
Current
consumption
(A)
Model
Standards
5 V
24 V
0.06
(See
0.18
CJ1W-PTS15
note
2.)
UC1, CE
0.25
CJ1W-PTS51
31