Installation
Instructions
IT] PROVIDE ADEQUATE
GAS SUPPLY
Your range is designed
to operate
at a pressure
of 4" of
water column
on natural
gas or, if designed
for LP gas
(propane
or butane),
10" of water colmnn.
Make sure you are supplying
your range widl die type
of gas for which
it is designed.
This range
is convertible
for use on natural
or
propane
gas. If you decide
to use dlis range on I,P gas,
conversion
must be made by a qualified
LP installer
before
attempting
to operate
the range
on dmt gas.
For proper
operation,
die pressure
of natural
gas
supplied
to the regulator
must be between
4" and 13"
of water cohmm.
For LP gas, die pressure
supplied
must be between
10"
and 13" of water cohmm.
_4qlen checking
for proper
operation
of die regulator,
tile inlet pressure
must be at least 1" greater
dmn tile
operating
(manifold)
pressure
as given above.
The pressure regulator located at the inlet of die range
manifold must remain in the supply line regardless of
whedler naumd or LP gas is being used.
A flexible metal appliance connector
used to connect die
range to the gas supply line should have an I.D. of 1/2"
and be 5 feet in length for ease of installaOon. In Canada,
flexible connectors must be single wall metal connectors
no longer than 6 feet in length.
CONNECT THE RANGE TO GAS
Shut off the main gas supply valve before disconnecting
the old range and leave it off until the new hookup
has
been completed.
Don't forget to relight the pilot on other
gas appliances
when you turn the gas back on.
Because
hard piping
restricts
movement
of the range,
the use of a CSA Inmrnafional-cerfified
flexible metal
appliance
connector
is recommended
unless local codes
require
a hard-piped
connection.
Never use an old connector when installing a new range.
If the hard piping method is used, you must carefidly
align the pipe; the range cannot be moved after the
connection
is made.
To prevent
gas leaks, put pipe joint compound
on, or
wrap pipe thread
tape with Teflon*
around,
all male
(exmrnal)
pipe threads.
A. Install a manual
gas line stmt-offvalve
in the gas line in
an easily accessed
location
outside
of the range.
Make
sure everyone
operating
the range knows where
and
how m shut off" the gas supply m the range.
B. Install male 1/2" flare union
adapter
to the 1/2" NPT
inmrnal
thread
at inlet of regulator.
Use a backup
wrench
on the regulator
fitting
m avoid damage.
When installing die range flom die flont, remove die
90 ° elbow for easier installation.
C. Install male 1/2" or 3/4" flare union adapter m die
NPT inmrnal dnead of the manual shut-off valve,
raking care m back-up the strut-off valve m keep it
flom arming.
D. Connect flexible metal appliance connector
to the
adapter on the range. Position range m permit
connection
at the strut-off valve.
E.
When
all connections
have been made,
make sure
all range
controls
are in die offposifion
and turn on
die mMn gas supply valve. Use a liquid leak detector
at all joints
and connections
to check for leaks in
die system.
WARNING:
DO NOT
USE A FLAME
TO
CHECK
FOR
GAS LEAKS.
When
using
test pressures
greater
than
1/2 psig to
pressure
test tile gas supply
system
of tile residence,
disconnect
the range
and individual
strut-off
valve
flom
the gas supply
piping.
When
using
test pressures
of 1/2 psig or less to test the gas supply
system,
simply
isolate
the range
flom
the gas supply
system
by closing
the individual
shut-off
vane.
*Teflon: