3.3.15 Sensor Plate (Inlet)
(1) Remove the upper cover (see 3.3.1).
(2) Remove the lower base unit (see 3.3.7).
(3) Press the clamps of three sensor plates (inlet) 1, and remove the sensor plates by pressing
them upward from the bottom side.
1
1
Clamp
Clamp
Paper sensor
Inlet sensor 1
Inlet sensor 2
3 - 21