Download Print this page

Craftsman 580.329180 Owner's Manual page 6

120/240 volt electric start 7500 watt ac generator

Advertisement

Available languages

Available languages

KNOW YOUR GENERATOR
Read the owner's manual and safety rules before operating your generator.
Compare the illustrations with your generator to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
Circuit Breakers (AC)
12 Volt DC,
10 Amp Receptacle
Idle Control
Switch
120 Volt AC, 30 Amp
Locking Receptacle
120/240 Volt AC, 30 Amp
Locking Receptacle
Fuel Tank
Choke Lever
Run/Stop
Cleaner
Spark A"_rester Muffler
120 Volt AC, 20 Amp
Duplex Receptacle
120/240 Volt AC,
50 Amp Receptacle
Grounding Lug
12 Volt DC, 10 Amp Receptacle --This
receptacle
allows you to recharge a 12 Volt DC storage battery
with provided battery charge cables.
120 Volt AC, 20 Amp, Duplex Receptacle
--
Supplies electrical power for the operation of 120 Volt
AC, 20 Amp, single phase, 60 Hz electrical lighting,
appliance, tool and motor loads.
120 Volt AC, 30 Amp Locking Receptacle --
Supplies electrical power for the operation of 120 Volt
AC, 30 Amp, single phase, 60 Hz electrical lighting,
appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking
Receptacle
--
Supplies electrical power for the operation of 120
and/or 240 Volt AC, 30 Amp, single phase, 60 Hz
electrical lighting, appliance, tool and motor loads.
120/240 Volt AC, 50 Amp Receptacle -- Supplies
electrical power for the operation of 120/240 Volt AC,
50 Amp, single phase, 60 Hz, welder or motor loads.
Air Cleaner -- Filters intake air as it is drawn into the
engine.
Choke Lever--
Used when starting a cold engine.
Circuit Breakers
(AC) -- Each receptacle is provided
with a push-to-reset circuit breaker to protect the
generator against electrical overload.
Fuel Tank -- Tank holds 8 U.S. gallons of fuel.
Grounding
Lug -- Ground the generator to an
approved earth ground here. See page 8 for details.
Idle Control Switch -- The idle control runs the
engine at normal (high) speeds when there is an
electrical load present and runs the engine at idle
(low) speeds the rest of the time.
Run/Stop
Switch -- Must be in "Run" position to start
engine. Set to "Stop" to stop a running engine.
Spark Arrester
Muffler -- Muffler lowers engine
noise and is equipped with a spark arrester screen.

Advertisement

loading