Dell PS-M4110 User Manual page 101

Firmware version 4.3
Hide thumbs Also See for PS-M4110:
Table of Contents

Advertisement

3.
Specify the events for which alerts must be generated:
racadm config -g cfgAlerting -o cfgAlertingFilterMask <mask value>
where <mask value> is a hex value between 0x0 and 0xffffffff.
To obtain the mask value, use a scientific calculator in hex mode and add the second values of the individual masks
(1, 2, 4, and so on) using the <OR> key.
For example, to enable trap alerts for Battery Probe Warning (0x2) , Power Supply Failure (0x1000) , and KVM failure
(0x80000) , key 2 <OR> 1000 <OR> 200000 and press the <=> key.
The resulting hex value is 208002, and the mask value for the RACADM command is 0x208002.
Table 14. Event Traps Filter Masks
Event
Fan Probe Failure
Battery Probe Warning
Temperature Probe Warning
Temperature Probe Failure
Redundancy Degraded
Redundancy Lost
Power Supply Warning
Power Supply Failure
Power Supply Absent
Hardware Log Failure
Hardware Log Warning
Server Absent
Server Failure
KVM Absent
KVM Failure
IOM Absent
IOM Failure
Firmware Version Mismatch
Chassis Power Threshold Error
SDCARD Absent
SDCARD Error
Chassis Group Error
Server Sleeve Absent
Fabric Mismatch
4.
Enable traps alerts:
racadm config -g cfgTraps -o cfgTrapsEnable 1 -i <index>
Filter Mask Value
0x1
0x2
0x8
0x10
0x40
0x80
0x800
0x1000
0x2000
0x4000
0x8000
0x10000
0x20000
0x40000
0x80000
0x100000
0x200000
0x400000
0x1000000
0x2000000
0x4000000
0x8000000
0x10000000
0x20000000
101

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chassis management controller

Table of Contents