Connect Vent System; Make Electrical Connection - Whirlpool W10018010 Installation Instructions And Use & Care Manual

36" (91.4 cm) wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

2. Level the blower housing with leveling screws in mounting
hooks, using a level across bottom of blower housing.
3. Remove the metal grease filter and secure the blower
housing with one screw in the bottom hole located in the rear
of the blower.
A. Rear of blower housing
B. Bottom 5 x 35 screw hole

Connect Vent System

Vented Installations Only
1. Fit vent system over transition piece.
2. Seal connection with clamps.
Non-vented (recirculating) Installation
1. Assemble the 3 parts of the deflector with 2 - 3.5 x 6.5 screws
provided. The assembled deflector should be sized to fit the
width of the vent cover bracket installed earlier.
A. Vent cover bracket width
B. Deflector
C. 3.5 x 6.5 mm screws
2. Connect the deflector to the vent cover bracket using
4 - 3.5 x 6.5 screws provided.
A. Vent cover bracket
B. 3.5 x 6.5 mm screws
3. Measure length of 8" (20.3 cm) vent needed to connect the
transition to the deflector.
NOTE: Vent should fit up inside deflector a minimum of
1" (2.5 cm).
4. Install vent between the transition and the deflector.
5. Seal all connections with clamps.
8
A
B
C
A
B
A
B

Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout.
A
B
A. Knockout
B. Terminal box cover
4. Install the UL listed or CSA approved strain relief.
A
B
A. ½" conduit
B. Terminal box cover
C. UL listed or CSA approved strain relief
D. Green (or bare) wire connected to yellow-green wire
E. White wires
F. Black wires
C
D
E
F

Advertisement

Table of Contents
loading

Table of Contents