Select The Best Location - Danby Designer DAC6003D Use And Care Manual

Hide thumbs Also See for Designer DAC6003D:
Table of Contents

Advertisement

Available languages

Available languages

Because the compressor Is located on the controls
side of the unit (right side), this side will be heavier
and more awkward to manipulate° Inadequate
support on control side of the unit can result in
personal injury and damage to your unit and
property. Therefore, it is recommended to have
someone assist you during the insial/ation of this
unit..
Your unit Is designed to evaporate condensation
under normal conditions. However, under
extreme humidity conditions, excess condensation
may cause basepan to overflow to the outside_
The Unit should be installed where condensation
run-off cannot drip on pedestrians or ne}ghboring
properties
A drain tube connection (exctuding hose) is provided
to redirect condensation ovedlow See Fig,.25
1, Select the Best Location
Ao This room air conditioner ts destgned lo fit easily
into a single or double hung window. However,
since window designs vary, it may be necessary
to make some modifications for sate, proper
Installation.
Bo Make sure window and frame is structurally
sound and free from dry and rotted wood,
C. For maximum efficiency, install the air condilioner
on a side of a house or building which favors
more shade than sunlight_ If the unit is tn direct
sunlight, it is advisable to provide an awning over
the unit,.
Co Providesufficient clearance around the cabinetto
a!lowfor ample atr circulation through the unit,
See Fig, 2, The rear of the unit should be
outdoors and not in a garage norinside a
building. Keep unit as faraway as possible from
ob_tacleslobstructionsand at least 30" above the
floororground, Curtainsand other objectswtth]n
a roomshould be prevented frombrookingthe air
flow.
E. Be certain the proper electrical outlet is within
reach of the Inslallationo Use only a single
outlet circuit rated at 15 ampso All wiring should
be in accordance with loca! and national
electrical codes.
F. DO NOT USE "REGULAR" EXTENSION CORDS
WITH THIS UNIT, If it is necessary to use an
extension cord to connect your air conditioner,
use an approved "air conditioner" extension cord
only (available at most local hardware stores)
G. DO NOT insta|l unit where leakage of combustible
gas is suspected. Your air conditioner may fail to
operate In air containing oils (including machine
oils), sulfide gas, near hot springs, etc...
30"
Slde
Min
obstrucllon
Ground
,,_>
FIg_2