Product Specifications; General Recommendations; Generator Maintenance - Craftsman 580.327122 Owner's Manual

2500 watt ac generator
Table of Contents

Advertisement

Available languages

Available languages

MAINTENANCE
SCHEDULE
Follow the hourly or calendar intervals, whichever occurs first.
More frequent service is required when operating in adverse conditions noted below.
Maintenance Operation
Check oil level
X
Change oil :1:
Clean spark arrester screen
Service air cleaner cartridge
Replace spark plugs
:1: Change oil after first 2 hours of operation then after every 50 hours or every season.
* Change oil every 25 hours when operating under heavy load or in high temperatures.
** Clean more often under dirty or dusty conditions. Replace cleaner parts if very dirty.
20 Hours or
25 Hours or
50 Hours or
Every 5 Hours Every Season
Every Season Every Season
100 Hours or
Every Season
X
PRODUCT
SPECIFICATIONS
Generator
Specifications
Rated RunningWatts .........
2,500 Watts (2.5kW)
Rated Surge Watts ...........
3,125 Watts (3.1kW)
Rated Voltage ...............
120 Volts AC
Rated Maximum Current
at 120 Volts
................
20.8 Amperes
Rated Frequency
............
60 Hz at 3600 rpm
Phase .....................
Single Phase
Engine
Specifications
Rated Horsepower ...........
6.0 at 3600 rpm
Displacement
...............
195cc
Spark Plug Type:
............
Champion RN4C or
Equivalent
Set Gap To: ...........
0.030inch (0.76mm)
Gasoline Capacity ............
1 U.S. gallon
GENERAL
RECOMMENDATIONS
The generator warranty does not cover items that
have been subjected to operator abuse or negligence.
To receive full value from the warranty, operator must
maintain generator as instructed in this manual.
Some adjustments will need to be made periodically to
properly maintain your generator.
All adjustments in this section should be made at least
once each season. Follow the requirements
in the
"Maintenance Schedule" chart shown above.
NOTE: Once a year you should clean or replace the
spark plug and replace the air filter. A new spark plug
and clean air filter assure proper fuel-air mixture and
help your engine run better and last longer.
GENERATOR
MAINTENANCE
Generator maintenance consists of keeping the unit
clean and dry. Operate and store the unit in a clean
dry environment where it will not be exposed to
excessive dust, dirt, moisture or any corrosive vapors.
Cooling air slots in the generator must not become
clogged with snow, leaves,or any other foreign
material.
Check the cleanliness of the generator frequently and
clean when dust, dirt, oil, moisture or other foreign
substances are visible on its exterior surface.
NOTE: Do Not use a garden hose to clean generator.
Water can enter the engine fuel system and cause
problems. In addition, if water enters the generator
through cooling air slots, some of the water will be
retained in voids and cracks of the rotor and stator
winding insulation. Water and dirt buildup on the
generator internal windings will eventually decrease
the insulation resistance of these windings.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents