Performance
Data Sheet
SmartWater Filtration System
GWF / HWF Cartridge
This system
has been tested according
to NSF/ANSI 42/53 for reduction
of the substances
listed below.
The concentration
of the indicated
substances
in water
entering
the system
was reduced to a concentration
less than or equal to the permissible
limit for water
leaving
the system,
as specified
in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered
usage)
Parameter
Chlorine
T&O
Particulate**
Standard No. 53: Health Effects
USEPA
HCL
Standard
No. 42: Aesthetic
Effects
Influent
Effluent
Challenge Concentration
Average
Maximum
2.0 mg/L+ 10%
0.02 ppm
0.05 ppm
at least 10,000 partides/mL
3,978
7,800
% Reduction
Average
Minimum
98.90%
97.57%
98.00%
96.10%
Min. Required
Reduction
_>50%
_>85%
Parameter
Effluent
USEPA
MCL
1NTU***
99.95%Reduction
15 ppb
15 ppb
0.0002 ppm
0.005 ppm
0.100 ppm
99%
Influent
Challenge Concentration
11 + 1 NTU***
Minimum 50,000 L
0.15 mg/L+ 10%
0.15 mg/L+ 10%
0.002 mg/L+ 10%
0.009 mg/L+ 10%
0.210 mg/L+ 10%
10_to 10_fibers!L;
fibers greater than
10 micrometers in length
Average
Maximum
Turbidity
0.07 NTU
0.1 NTU
Cysts
26
55
Lead at pH 6.5
i ppb
1 ppb
Lead at pH 8.5
1.8 ppb
4.5 ppb
Lindane
0.00005 ppm
0.00005 ppm
Atrazine
0.002 ppm
0.005 ppm
2,4-D
0.042 ppm
0.090 ppm
Asbestos
0.32 MFL/ml
1.2 MFL/ml
% Reduction
Average
Minimum
99.71%
99.59%
99.97%
99.95%
99.57%
99.57%
98.8%
97.15%
91.95%
91.95%
76.19%
64.28%
84.89%
67.65%
99.95%
99.82%
Hin. Required
Reduction
0.5 NTU
> 99.95%
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.005 mg/L
0.07 mg/L
99%
4-
o
Tested using a flow rate of O.5 gpm; pressure
of 60 psig; pH of 7.5 +_0.5; temp. of 20 ° _ 2.5 C
** Measurement
in Particles/mt.
Particles used were 0.5-1 microns
*** NTU=Nephelometric T urbidityunits
Operating
Specifications
[] CapacitLl: certified for up to 300 gallons (1155 I);up to six months for models without a replacement filter indicator light; up to one
gear for models with a replacement filter indicator light
[] Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
[] Temperature: 33-100°F (0.6-38°C)
[] Flow rate: 0.5 gpm (1.9 Ipm)
General Installation/Operation/Maintenance
Requirements
[] Flush new cartridge at full flow for 3 minutes to purge out trapped air.
[] Replace cartridge when flow becomes too slow.
Special Notices
[] Installation instructions, parts and service availabilitLl, and standard warrantLl are included with the product when shipped.
[] This drinking water sLlstem must be maintained according to manufacturer's instructions, including replacement of filter
cartridges.
[] Do not use with water that is microbiologicallLl unsafe or of unknown qualitLl without adequate disinfection before or after
the sLlstem. SLlstems certified for cLlst reduction mall be used on disinfected water that mall contain filterable cLlsts.
[] The contaminants or other substances removed or reduced bLl this water treatment sLlstem are not necessarilLl in Llour water.
[] Check for compliance with the state and local laws and regulations.
[] Note that while the testing was performed under standard laboratorLl conditions, actual performance mall varLl.
SLlstems must be installed and operated in accordance with manufacturer's recommended procedures and guidelines.
System Tested and Certified by NSF International against ANSI/NSF Standard 42 & 55 for the
reduction of:
Standard No. 42: Aesthetic Effects
Chemical Unit
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction, Class I
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead and Atrazine Reduction
Lindane and 2,4-D Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cyst and Asbestos Reduction
Manufactured for: General Electric Company, Louisville, KY40225
41