Led Hard Drive Led Combinations - HP StorageWorks 9100 - Extreme Data Storage System User Manual

Extreme data storage system
Hide thumbs Also See for StorageWorks 9100 - Extreme Data Storage System:
Table of Contents

Advertisement

Table 2 LED Hard drive LED combinations
Online/activity LED (green)
On, off, or flashing
On, off, or flashing
On
On
Flashing regularly (1 Hz)
Flashing regularly (1 Hz)
Flashing irregularly
Flashing irregularly
Off
Off
Off
NOTE:
Predictive failure alerts are generated by system management software and occur only when the
enclosure is connected to a Smart Array controller. The ExDS9100c includes a Smart Array controller.
Fault/UID LED (amber/blue)
Alternating amber and blue
Steadily blue
Amber, flashing regularly (1 Hz)
Off
Amber, flashing regularly (1 Hz)
Off
Amber, flashing regularly (1 Hz)
Off
Steadily amber
Amber, flashing regularly (1 Hz)
Off
9100c Extreme Data Storage System user guide
Interpretation
The drive has failed, or a predictive
failure alert has been received for
this drive; it also has been selected
by a management application.
The drive is operating normally,
and it has been selected by a
management application.
A predictive failure alert has been
received for this drive. Replace the
drive as soon as possible.
The drive is online, but it is not
currently active.
Do not remove the drive. Removing
a drive may terminate the current
operation and cause data loss.
The drive is part of an array that
is undergoing capacity expansion
or a stripe size migration, but a
predictive failure alert has been
received for this drive. To minimize
the risk of data loss, do not replace
the drive until the expansion or
migration is complete.
Do not remove the drive.
Removing a drive may terminate
the current operation and cause
data loss. The drive is rebuilding,
or it is part of an array that is
undergoing capacity expansion or
a stripe size migration.
The drive is active, but a predictive
failure alert has been received for
this drive. Replace the drive as
soon as possible.
The drive is active, and it is
operating normally.
A critical fault condition has been
identified for this drive, and the
controller has placed it offline.
Replace the drive as soon as
possible.
A predictive failure alert has been
received for this drive. Replace the
drive as soon as possible.
The drive is offline, a spare, or not
configured as part of an array.
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 9100c