Sas And Sata Hard Drive Led Combinations - HP 600 Maintenance And Service Manual

Hp storageworks 600 modular disk system maintenance and service guide
Hide thumbs Also See for 600:
Table of Contents

Advertisement

SAS and SATA hard drive LED combinations

Online/activity
LED (green)
On, off, or flashing Alternating amber
On, off, or flashing Steadily blue
On
On
Flashing regularly
(1 Hz)
Flashing regularly
(1 Hz)
Flashing irregularly Amber, flashing
Flashing irregularly Off
Off
Off
Off
Fault/UID LED
Interpretation
(amber/blue)
The drive has failed, or a predictive failure alert has been received
and blue
for this drive; it also has been selected by a management
application.
The drive is operating normally, and it has been selected by a
management application.
Amber, flashing
A predictive failure alert has been received for this drive.
regularly (1 Hz)
Replace the drive as soon as possible.
Off
The drive is online, but it is not currently active.
Amber, flashing
Do not remove the drive. Removing a drive may terminate the
regularly (1 Hz)
current operation and cause data loss.
The drive is part of an array that is undergoing capacity expansion
or a stripe size migration, but a predictive failure alert has been
received for this drive. To minimize the risk of data loss, do not
replace the drive until the expansion or migration is complete.
Off
Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is rebuilding, or it is part of an array that is undergoing
capacity expansion or a stripe size migration.
The drive is active, but a predictive failure alert has been received
regularly (1 Hz)
for this drive. Replace the drive as soon as possible.
The drive is active and it is operating normally.
Steadily amber
A critical fault condition has been identified for this drive and the
controller has placed it offline. Replace the drive as soon as
possible.
Amber, flashing
A predictive failure alert has been received for this drive. Replace
regularly (1 Hz)
the drive as soon as possible.
Off
The drive is offline, a spare, or not configured as part of an array.
Component identification 59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 600

Table of Contents