RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES
MINIMUM HORIZONTAL TERMINATION INSTALLATIONS
Planning Your venting Installation
See page 10 for Exterior Vent Termina-
tion requirements. The H25 is approved for
a minimum horizontal termination with the FPI
Riser Vent Kit. See the diagram for minimum and
maximum pipe lengths.
When planning your installation, it will be nec-
essary to select the proper length of vent pipe
for your particular requirements. Determine the
minimum clearance to combustibles from the
rear of the unit to the wall. It is also important to
note the wall thickness. Before cutting the vent
hole through the wall ensure that ALL vent and
termination clearances (see page 10) will be
met.
*If this is an outside corner, the minimum dis-
tance between the vent and the outside corner
is 6" (15cm). See "F" on the diagram on page 10.
NOTE: Ensure compliance with the outside vent
terminal location before cutting hole as both
dimensions must be met.
Hampton H25 Direct Vent Freestanding Gas Stove
You will require the following components with your new Hampton Rear Vent Direct Vent
Freestanding Gas Stove. Please review your product to make sure you have everything you need.
In the event that you are missing any part, contact your dealer.
Decorative brass or chrome trim kits are available from Simpson
Dura-Vent for their wall thimbles, as well as a square wall thimble
cover.
Note: These are the minimum pieces re-
quired. Other parts may be required
for your particular installation.
Minimum components for a Horizontal Installation:
640-944
Horizontal Termination Kit which includes:
1
6-5/8" Dia. x 18" Black Pipe
1
4" Dia. x 18" Aluminum Vent
1 946-202
Wall Penetration Heat Shield (Wall Thimble) (2 pcs)
1 640-530/P Riser Vent Terminal
1 640-545/P Decorative Wall Trim (Black)
1 948-128
Tube Mill-Pac
Screws
946-219
1 Adapter
Optional Components:
946-204
45
o
Elbow - 6-5/8" Black pipe
and 4" Aluminum Vent
946-205
Vinyl Siding Shield for Riser Vent
Terminal
946-208/P
Vent Guard
940
Square Wall Thimble Cover*
981
Snorkel Termination (36")*
982
Snorkel Termination (14")*
942
Wall Penetration
Heat Shield*
* Simpson Dura-Vent components
INSTALLATION