WARNING:
If the information in these instructions are not
followed exactly, a fire or explosion may result
causing property damage, personal injury or loss
of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapours and liquids in the vicinity of this or any
other appliance.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
Tested by:
918-101b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
www.hampton-fire.com
MODELS:
H25-NG Natural Gas
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Installation Manual
H25-LP Propane
This appliance may only be
installed in an aftermarket per-
manently located, manufac-
tured (USA only) or mobile
home, where not prohibited
by local codes.
This appliance is only for use
with the type of gas indicated
on the rating plate. This appli-
ance is not convertible for use
with other gases, unless a cer-
tified kit is used.
Owners &
01/09/06

Advertisement

Table of Contents
loading

Summary of Contents for HAMPTON BAY Hampton H25-NG

  • Page 1 Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 918-101b 01/09/06 FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4...
  • Page 2: Unit Dimensions

    Congratulations! You are the owner of a state-of-the-art Hampton Gas Stove by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The H25 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Page Page Safety Label Cathedral Ceiling Installations ........25 Support Extension - Round or Square ....... 25 Safety Labels ............4 High Elevation ............25 Gas Connection ............25 Installation System Data Chart ..........25 Aeration Adjustment ..........25 Specifications ............
  • Page 4: Safety Labels

    SAFETY LABEL This is a copy of the label that accompanies NOTE: Hampton units are constantly being each Direct Vent Freestanding Gas Stove. We improved. Check the label on the unit and if there have printed a copy of the contents here for is a difference, the label on the unit is the correct your review.
  • Page 5: Installation

    INSTALLATION 501A, and with CAN/CSA Z240-MH Mobile IMPORTANT: DUE TO HIGH TEMPERATURES, Home Standard in Canada. THE APPLIANCE SHOULD BE LO- SAVE THESE CATED OUT OF TRAFFIC AND This appliance installation must comply with the INSTRUCTIONS manufacturer's installation instructions and lo- AWAY FROM FURNITURE AND cal codes, if any.
  • Page 6: General Safety Information

    INSTALLATION 5) This appliance is Listed for Alcove installa- 9) To prevent injury, do not allow anyone who CLEARANCES TO tions, maintain minimum Alcove clearances is unfamiliar with the operation to use the COMBUSTIBLES as follows, minimum width of 34-3/4" fireplace.
  • Page 7: Locating Your Gas Stove

    INSTALLATION OPTIONAL FAN LOCATING YOUR 4) Remove the nylon hole plug from the control panel. GAS STOVE INSTALLATION 5) Install the fan speed controller onto the control panel and secure with nut and When selecting a location for your stove, en- Fan Kit Contains: washer.
  • Page 8 INSTALLATION 9) Place the blower close to the base of the unit and feed the long red 12) Before re-attaching the rear access panel, the valve wires and the and black wires through the opening of the base of the unit and fan wires need to be connected.
  • Page 9: Venting Introduction

    3) Installation of any component part not man- POSITION ufactured or approved by Simpson Dura- Vent or FPI Fireplace Products International Note: These flue pipes must not be Ltd. To set the Vent restriction as indicated in the connected to any other appliance.
  • Page 10: Exterior Vent Terminal Locations

    INSTALLATION EXTERIOR VENT TERMINAL LOCATIONS Hampton H25 Direct Vent Freestanding Gas Stove...
  • Page 11: Rigid Pipe Venting Components List

    INSTALLATION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI. Description Simpson Dura-Vent Selkirk Amerivent Direct VentGS Direct-Temp Direct Vent 6" Pipe Length, Galvanized 4DT-6 6" Pipe Length, Black 908B 4DT-6B 7" Pipe Length, Galvanized 7"...
  • Page 12: Rigid Pipe Venting Systems Horizontal Or Vertical Terminations

    The FPI AstroCap and FPI Riser Vent terminal is certified for installations using FPI venting systems as well as Simpson Dura-Vent®, Direct Vent GS, American Metal Products, Ameri Vent Direct vent and Selkirk Direct-Temp. FPI...
  • Page 13: Venting Arrangements - Horizontal Terminations

    The two diagrams show all allowable combinations of straight horizontal ter- mination with one 45 elbow off the unit and Dura-Vent Snorkel or FPI Riser Vent. Restrictor position "A". Riser Vent Termination Dura-Vent Snorkel Termination Hampton H25 Direct Vent Freestanding Gas Stove...
  • Page 14: Horizontal Venting With Two Elbows

    INSTALLATION Horizontal Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. With these options, maxi- Option H + H1 mum total pipe length is 30 2' Min. 4' Max. feet with minimum of 6 feet 3' Min. 5' Max.
  • Page 15: Vertical Venting With Two Elbows

    INSTALLATION Vertical Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option V V + V1 With these options, max. total pipe length is 30 feet with min. 1' Min. 4' Max. 2' Min. of 6 feet total vertical and max. 2' Min.
  • Page 16: Vertical Termination With Co-Linear Flex System

    INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM Masonry chimneys may take various contours which the flexible liner will accommodate. THE APPLIANCE MUST NOT BE However, keep the flexible liner as straight as possible , avoid unnecessary bending. CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL The Air Intake pipe must be attached to the inlet air collar of the termination cap.
  • Page 17: Horizontal Termination Kit

    INSTALLATION DV STOVE HORIZONTAL VENT KIT DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed to install the H25 Direct Vent unit with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown on page 20.
  • Page 18 INSTALLATION 13) Secure the 4" dia. flex liner with adapter onto the stove collar. Put a bead of Mill-Pac around the appliance adapter and secure with 3 screws (#8 x 1/2, stainless steel). 14) Attach the 45 elbow onto the starter collar by sealing with Mill-Pac and/or high tem- perature silicone and securing with 3 of the #8 x 1/2"...
  • Page 19: Residential And Manufactured Homes / Mobile Homes Minimum Horizontal Termination Installations

    The H25 is approved for Decorative brass or chrome trim kits are available from Simpson a minimum horizontal termination with the FPI Dura-Vent for their wall thimbles, as well as a square wall thimble Riser Vent Kit. See the diagram for minimum and cover.
  • Page 20: Dura-Vent Termination Kits

    Terminal 1 Horiz. Sq. Term. Cap Part# 640-530/P The FPI AstroCap is certified for installations using FPI venting systems as well as Simpson Dura-Vent® and Direct Vent GS. The FPI AstroCap is the proprietary trademark of FPI Fireplace Products International Ltd.
  • Page 21: Dura-Vent Venting Components Parts List

    INSTALLATION Parts not supplied by Dura-Vent combustible material, i.e. masonry block or DURA-VENT VENTING 946-506/P Vent Guard (Optional) concrete, a 7" diameter hole is acceptable. COMPONENTS 640-530 Riser Vent Terminal (Optional) 948-128 Vinyl Siding Shield for Riser Vent Terminal The Simpson Dura-Vent Direct Vent System 946-228 Horizontal Square Termination Cap offers a complete line of component parts for...
  • Page 22: Dura-Vent Vertical Termination Installation

    INSTALLATION NOTE: For Snorkel terminations in ABOVE 7) Install the Backing Plate into the wall pene- 8) Slide the decorative wall thimble up to the grade installations, follow national tration heat shield and attach using 4 wall surface being careful not to scratch or local code requirements.
  • Page 23: Offset Chart

    INSTALLATION the venting system. You may wish to relo- 7) Ensure vent is vertical and secure the base cate the appliance or to offset, as shown in of the flashing to the roof with roofing rails, diagram 8 to avoid cutting load bearing slide storm collar over the pipe section and members.
  • Page 24: Converting A Class-A Metal Chimney Or Masonry Chimney To A Direct Vent System

    INSTALLATION CONVERTING A CLASS- 4) Pass the flex pipe down through the center Approved for US Installations Only of the chimney system, and center the The use of an existing chimney as an air A METAL CHIMNEY OR adaptor on the top of the chimney pipe. Drill intake is not covered under the ANSI four 1/8"...
  • Page 25: Cathedral Ceiling Installations

    INSTALLATION half of the flashing should be under the CATHEDRAL CEILINGS WATER SOLUTION OR GAS LEAK shingles. DETECTOR. DO NOT USE OPEN FLAME FOR LEAK TESTING. Round Support (RDS) & 4) Assemble the desired lengths of Black Pipe and Elbows necessary to reach from the Square Support (SQS) appliance adapter up through the support Note: Prior to any pressure testing of...
  • Page 26: Gas Pipe Pressure Testing

    INSTALLATION To adjust the aeration: use the allen key to turn 4) Light the pilot and turn the valve to "ON" CONVERSION FROM the turning gear which will adjust the air shutter. position. Read manometer. NATURAL GAS TO Open the air shutter for a blue flame or close it for a more yellow flame.
  • Page 27 INSTALLATION 6) Pull off the pilot cap to expose the pilot orifice. 7) Unscrew the pilot orifice with the allen key and replace with the LP pilot orifice in the kit. 8) Remove burner orifice with a 1/2" wrench and discard. Use a wrench to hold on to the elbow behind the orifice.
  • Page 28: Log Set Installation

    INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the dia- 5) Place the 2 front logs on the front log locating pins. Ensure the back grams. If the logs are broken do not use the unit until they are of both logs rest against the tabs.
  • Page 29 INSTALLATION 6) Take the embers and place on the burner in the space between the 8) Test fire to ensure proper light off (make sure flame flows smoothly from one end of burner to the other). If there is any flame hesitation, 2 front logs.
  • Page 30: Optional Door Grill

    INSTALLATION DECORATIVE DOOR OPTIONAL WALL OPTIONAL REMOTE THERMOSTAT CONTROL GRILL INSTALLATION 1) Turn the Grill Latches on the Rear of the Use the Hampton Remote Control Kit approved A wall thermostat may be installed if desired. for this unit. Use of other systems may void your Door Grill as per the photo below.
  • Page 31: Final Check

    INSTALLATION CAUTION FINAL CHECK Any alteration to the product that causes Before leaving this unit with the customer, the sooting or carboning that results in dam- installer must ensure that the appliance is firing age to the exterior facia is not the re- correctly.
  • Page 32: Operating Instructions

    OPERATING INSTRUCTIONS 1) Turn stove OFF using the Burner "ON/OFF" OPERATING detectors in the house may go off at this time. switch remote or thermostat. Switches are Open a few windows to ventilate the room for INSTRUCTIONS located at the top right hand corner (rear) a couple of hours.
  • Page 33: Copy Of Lighting Plate Instructions

    OPERATING INSTRUCTIONS Copy of the Lighting Plate instructions Hampton H25 Direct Vent Freestanding Gas Stove...
  • Page 34: Normal Operating Sounds Of Gas Appliances

    MAINTENANCE 2) Clean glass (never when unit is hot), appli- NORMAL OPERATING CAUTION: ANY SAFETY SCREEN ance, and door with a damp cloth. Never OR GUARD REMOVED FOR SERV- SOUNDS OF use an abrasive cleaner. ICING AN APPLIANCE MUST BE GAS APPLIANCES 3) The heater is finished in a porcelain finish REPLACED PRIOR TO OPERAT-...
  • Page 35: Log Installation

    MAINTENANCE 1) Lift off the Cast Top. GENERAL VENT FAN MAINTENANCE MAINTENANCE If your fan requires maintenance or replace- ment, access to the fan is through the rear Conduct an inspection of the venting system access panel on the back of the unit. NOTE: the semi-annually.
  • Page 36: Removing And Installing Valve

    MAINTENANCE 6) Disconnect piezo wire. 3) Unclip the black and white wires from the 12) To remove the valve, remove the 4 screws fan motor. (2 per bracket) that hold the valve to the 7) Lift off the Cast Top and lift out the front valve bracket assembly.
  • Page 37: Parts List

    PARTS LIST MAIN ASSEMBLY Part # Description Part # Description Part # Description 137) * Hole Plug 0.375 942-421** Casting - Top W260260 Top Relief Frame Gasket 908-106 Decal Rear Control Panel 942-381** Casting - Leg 942-117 Top Relief Frame W260280 Top Relief Plate Gasket 942-431**...
  • Page 38 PARTS LIST BURNER & LOG ASSEMBLY Part # Description 350-574/P Valve Assembly S.I.T. - Natural Gas 910-378 Valve S.I.T. - Natural Gas 904-430 #42 Orifice - N.G. 910-190 Piezo Ignitor & Nut 908-672 Control Panel Decal 490-061 Switch Plate 936-170 Orifice Gasket 910-038 Pilot Assy-S.I.T.-3 flame-NG...
  • Page 39: Warranty

    At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. ie. as products evolve, field modifications or upgrades will not be performed.
  • Page 40 Dealer Name & Address: ________________________________________________ ______________________________________________________________________ Installer: ______________________________________________________________ Phone #: ______________________________________________________________ Date Installed: _________________________________________________________ Serial No.: _____________________________________________________________ Hampton is a trademark of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2005, FPI Fireplace Products International Ltd. All rights reserved.