MAINTENANCE

Inspection Of The Seals

At the start of each season, check gaskets on
the door, fuel door and ash door by using a strip
of paper which you will slip at several places
between the seal and the stove (see Diagram
28). If the gaskets need to be replaced use
only approved gasket and adhesive obtainable
from your FPI dealer. A proper high temperature
gasket adhesive is also required.
Diagram 28
22
Information On How To Clean
The Chimney
At the start of each season or every 3 tons
burned, check the accumulation of ashes inside
the chimney. It is important to clean the full
system including all lengths, T's and elbows.
Maintenance Of The
Battery System
Check that the grips are well connected on the
battery poles. Small test: start the stove without
fl ame (cold). After 30 seconds, disconnect the
plug which is connect to the wall socket. If the
stove is functioning that means that the battery
is well connected.
Never place a battery
directly on concrete as this can damage
the battery.
Type Of Cleaning Product To Use
For The Windows
Always use a proper cleaning product which
can be found at any hearth retailer, designed
for high temperature glass.