Installation; Installation Clearances To Combustibles; Reduced Clearances; Rear Exit - Stanley Errigal Installation And Operating Instructions Manual

Errigal woodburning range
Table of Contents

Advertisement

When installing, operating and maintaining a solid
fuel heater, respect basic standards of fire safety.
Read these instructions carefully before commenc-
ing the installation. Failure to do so may result in
damage to persons and property. Consult your local
municipal office, Fire Department and your insur-
ance representative to determine what regulations
are in force.
INSTALLATION CLEARANCES TO
COMBUSTIBLES
Front
Back
Oven Side
Oven Side with Optional
Shelf Fitted
Firebox Side
Single Wall Flue Pipe
(2130mm)
(300mm)
Fig.6

REDUCED CLEARANCES

These clearances may be reduced by the applica-
tion of protection to combustible walls and ceilings.
ULC/UL Labelled Heat Shields installed in accor-
dance with the manufacturers instructions or shields
complying with the requirements of "Installation
Code for Solid Fuel Fired Appliances CAN31336" or
"Standard for Chimneys, Fireplaces and Ve n t s
NFPA No. 211."
48"
1220mm
16"
400mm
6"
150mm
10"
250mm
12"
300mm
18"
460mm
(2130mm)
(150mm)

INSTALLATION

(2130mm)
(300mm)
(460mm)
(2130mm)
(400mm)
(300mm)
Fig.7

REAR EXIT

Back
Oven side
Firebox Side
(300mm)
Fig.8
4
(150mm)
(150mm) clearance or
less
(250mm)
(2130mm)
6"
6"
12"
REAR EXIT
(150mm)
(225mm)
(200mm)
(150mm)
(100mm)
150mm
150mm
300mm