Epson EMP-280 User Manual page 36

Epson projector user manual
Hide thumbs Also See for EMP-280:
Table of Contents

Advertisement

Problem Solving
Status
Cause
Lamp Error
Red
Lamp Failure
Lamp Cover Open
Red
Airflow Error
Red
Red
Check the following two points.
• Take out the lamp and check if it is cracked. s
• Clean the air filter. s
p.48
If it is not cracked - Re-fit the lamp and turn on the power.
If the error continues - Replace the lamp with a new lamp and turn on the power.
If the error continues - Stop using the projector, disconnect the power cable from the electrical outlet, and contact
your local dealer or the nearest address provided in the Epson Projector Contact List.
sEpson Projector Contact List
If it is cracked - Replace it with a new lamp, or contact your local dealer for further advice. If replacing the lamp
yourself, be careful to avoid pieces of broken glass (you cannot continue projecting until the lamp is replaced).
Projector Contact List
Check that the lamp cover and the lamp are securely installed. s
If the lamp cover or the lamp is not securely installed, the lamp does not switch on.
When using at an altitude of 1500 m or more, set "High Altitude Mode" to "On". s
The filter is clogged with dust or dirt. Clean or replace the air filter. s p.48,
Remedy or Status
p.53
p.53
p.29
56
36
: Lit
: Flashing:
: Off
sEpson