Installation - Payne Gas Furnace User's Information Manual

Condensing gas furnace
Hide thumbs Also See for Gas Furnace:
Table of Contents

Advertisement

IF FURNACE FAILS TO OPERATE:
Follow this checklist step by step, advancing to the next step only if flunace tails to start.
• Check thelanostat tbr proper temperattue. Is thermostat set above room temperattue?
• Is thermostat set on HEAT'?
• Check fi_ses and chcuit breakers. Is electrical supply on'?
• Is manual shutoff valve in gas supply pipe in open position'? (Follow start-up procedmes if you open gas valve.)
NOTE: Tmn off electrical supply betk3re continuing with checklist.
• Is control switch on gas valve in ON position? (Follow stmt-up procedures if you must reset switch to ON.)
• Check manual reset flame rotlout switch located on the burner box. (See Fig. 1.) If furnace has experienced
high temperature
conditions, this switch wilt shut off the furnace. Reset it by pushing the button on the switch. If it trips again, shut down the
%rnace and call for service. See "Shutting Down Your Furnace" section in this manual.
• Check tbr obsln_ctions mound the vent termination.
If yore Nrnace still fails to operate, call yore service representatNe.
For your convenience, recoM the Nrnace product and serial m_mbers on back page. Should you ever requhe service, you wilt have
ready access to the intk)rmation needed by yore service representative.
This fmnace has a light emitting diode (LED) status code display to aid the installer, service technician, o1 homeowner while installing
o1 servicing the unit. The LED code can be seen by removing the main Nrnace door and viewing LED tlnough the view pog in the
blower access panel.
INSTALLATION
DATA
Date Installed
Dealer Name
Address
City_
State
Zip
Telephone
FURNACE
Product No.
Model No.
Serial No.
AIR CONDITIONER
OR HEAT PUMP
OUTDOOR
UNIT:
Product No.
Model No.
Serial No.
INDOOR COIL:
Product No.
Model No.
Serial No.
13

Advertisement

Table of Contents
loading

Table of Contents