Burner Performance

CAUTION:
Never cover control knobs or surrounding
control surface with utensils, towels, or other objects.
Never obstruct free air passage past the control knobs.
The knob openings have been sized to properly control air
entry to the interior of the appliance during operation.
This appliance has no air shutters. Primary air
adjustments are unnecessary. The burners are designed
to provide optimum aeration for all gases without air
5 BURNER MODEL (36" Wide)
FIGURE 16
JENN- AIR 36"
INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)
BURNER LOCATION
Right Front
Right Rear
Left Front
Left Rear
Center
Hi
17,000 / 14,000
2,200/2,200
9,200 / 9,100
1,500 / 1,500
9,200 / 9,200
1,500 / 1,500
12,000 / 10,500
1,500 / 1,500
5,000 / 4,000
1,100 / 1,100
shutters. When operating properly, burners should
produce clearly defined, even blue flames. If the flames
have yellow tips or are hazy and otherwise appear to
have insufficient air, obtain the services of a qualified
service technician. Some yellow tipping on LP gas is
normal.
Specified input rates are as shown in figures 16 and 17
below.
4 BURNER MODEL (30" Wide)
JENN- AIR 30"
INPUT RATES - NATURAL GAS / LP GAS (BTU/HR)
Lo
BURNER LOCATION
Right Front
Right Rear
Left Front
Left Rear
Center
11
FIGURE 17
Hi
17,000 / 14,000
1,800 / 1,800
9,200 / 9,100
1,300 / 1,300
12,000 / 10,500
1,300 / 1,300
5000 /
4000
650 / 650
- - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - -