Environmental Specifications - HP StorageWorks 12000 - Virtual Library System EVA Gateway User Manual

Hp storageworks 12000 gateway virtual library system user guide (ah814-96014, march 2010)
Hide thumbs Also See for StorageWorks 12000 - Virtual Library System EVA Gateway:
Table of Contents

Advertisement

Item
Packet buffer size
Latency
Throughput
Switching capacity
MAC address table size
Maximum heat dissipation
Voltage
Current
Power
Frequency

Environmental Specifications

1
Temperature
Relative humidity (noncondensing)
Altitude
Vibration
Shock
1
All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048 m
(10,000 ft) is applicable. No direct sunlight allowed.
2
Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage
corresponds to a pressure minimum of 70 KPa.
Specification
0.75 MB
< 5.6 µs (FIFO 64-byte packets)
up to 35.7 million pps (64-byte packets)
48 Gbps
8000 entries
164 BTU/hr
100-127 VAC/200-240 VAC
1.25 A /0.75 A
60 W
50/60 Hz
Operating
10°C to 35°C (50°F
to 95°F)
2
40% to 60%
-1000 ft to 10,000
ft
5-1000-5 Hz, 0.25
g, sinusoidal, 1
Octave/min., 3-axis
5 g, every 11ms,
1/2 sine pulse, 3
axis
Non-operating
Shipping
-40°C to 66°C (-
-40°C to 66°C (-
40°F to 150°F)
40°F to 150°F)
10% to 95%
5% to 95%
-1000 ft to 10,000
-1000 ft to 40,000
ft
ft
5-1000-5 Hz, 1.0
5-1000-5 Hz, 2.0
g, sinusoidal, 1
g, sinusoidal, 1
Octave/min., 3-axis
Octave/min., 3-axis
25 g, every 11ms,
30 g, every 11ms,
1/2 sine pulse, 3
1/2 sine pulse, 3
axis
axis
HP StorageWorks
235

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 12000 gateway virtual library system

Table of Contents