Appliance And Vent Clearances - Superior SDV35-N Installation Instructions Manual

Sdv35 direct-vent gas fireplaces
Hide thumbs Also See for SDV35-N:
Table of Contents

Advertisement

MINIMUM CLEARANCES TO COMBUSTIBLES
Hearth Extension A hearth extension is not required with this appliance. If a hearth extension is
used, do not block the lower control compartment door. Any hearth extension used is for appear-
ance only and does not have to conform to standard hearth extension installation requirements.
See Figure 7.
Wall Finishes / Surrounds / Mantels
Note: Combustible wall finish materials and/or surround materials must not be allowed to encroach
the area defined by the appliance front face (black sheet metal). Never allow combustible materials
to be positioned in front of or overlapping the appliance front face. See Figure 58 on Page 31.
Non-combustible materials, such as surrounds and other appliance trim, may be installed on the
appliance front face with these exceptions: they must not cover any portion of the removable glass
panel or louvers.
Vertical installation clearances to combustible mantels vary according to the depth of the mantel.
See Figure 7. Mantels constructed of non-combustible materials may be installed at any height
above the appliance opening; however, do not allow anything to hang below the hood.
NOTE: We recommend the use of high temperature paint (rated 175° F or higher) on the underside
of the mantel.
Mantel Clearances
Mantel Depth
14 (356)
12 (305)
10 (254)
8 (203)
6 (152)
4 (102)
12
10
8
(305)
(254)
(203)
(152)
Note - Hood shown as positioned with louvered panels.
Figure 7 -
Mantel and Hearth Extension Requirements
Model No.
Top Vent - with One 90 Degree Elbow
Secure Vent
SDV35
*49 (1245)
* Includes 3" clearance to combustibles (required above vent components)
Do not insulate the
space between the
appliance and the
area above it.
Shelf Height
(
see table)
Shelf Above Fireplace With Rear Venting
Figure 8 -
Shelf Height Minimum Clearances
8
Top of
Appliance
6
4
2
(102)
(51)
Combustible Shelf Height - Inches (millimeters)
Rear Vent - Straight Out the Back
Secure Flex
Secure Vent
(flex elbow)
*50-3/4 (1289)
37-1/2 (953)
Do not insulate the
space between the
appliance and the
area above it.
*Shelf Height
(
see table)
Shelf Above Fireplace With Top Venting
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Hearth Extension Requirements
3-3/4"
3-5/16"
Maximum thickness of
hearth extension when
fireplace is on the floor.
inches (millimeters)
Secure Flex
At 12" minimum
37-1/2 (953)
side wall clearance,
a combustible wall
can project to any
length .

Appliance and Vent Clearances

The appliance is approved with zero clearance to
combustible materials on all sides (as detailed
in Table 5), with the following exception: When
the appliance is installed with one side flush
with a wall, the wall on the other side of the
appliance must not extend beyond the front
edge of the appliance. In addition, when the
unit is recessed, the side walls surrounding the
unit must not extend beyond the front edge of
the unit. See Figure 3.
MINIMUM CLEARANCES
Back
Sides
Top Spacers
Floor
Bottom of Appliance
To Ceiling
Vent
SERVICE CLEARANCES
Front
Table 5
*Note: 3 in. (75 mm) above any horizontal/in-
clined vent component.
**Note: See Page 9, Step 1 for clearance
requirements to the nailing flange located
at each side of the unit and any screw heads
adjacent to it.
Minimum Distance to Unprotected Side Wall
Combustible materials may project beyond the sides of the fire-
place opening as long as they are kept within the shaded areas
illustrated here.
At 7" side wall
clearance, a
combustible wall
can project 12"
o
45
Protected wall shown in white
12
7
(305)
(178)
Inches (millimeters)
1/2 (13)
0 (0) Spacers
1/2 (13)
0 (0) Spacers
0 (0)
0 (0)
64 (1626)
3 (76)
*
Top
1 (25.4)
Sides & Bottom
Feet (meters)
3 ft. (0.9 m)
Top View of
Fireplace
Combustible Materials
Allowed In Shaded
5
(127)
Area "Safe Zone"
Combustible Walls
shown in dark gray
12
(305)
17
(432)
Inches (millimeters)
Figure 9

Hide quick links:

Advertisement

Table of Contents
loading