120/240 volt electric start 10,000 watt ac generator

Advertisement

120/240
Volt AC, 50 Amp Receptacle
Use a NEMA 14-50 plug with this receptacle. Connect
a 4-wire cord set rated for 250 Volts AC at 50 Amps to
the plug.
Y (Hot)
240 Volts AC
r__m
Frame Ground
AC_
W (Neutral)
NEMA 14-50
X (Hot)
Use this receptacle to operate 240 Volts AC, 60 Hz,
single phase loads requiring up to 10,000 watts
(10.0 kW) of power.
_
CAUTION!
Although this outlet states it has a
240 Volt 50 Amp rating (up to 12,500 watts), the
generator is only rated for 10,000 watts.
Powering loads that exceed the wattage/
amperage capacity of the generator can
damage it and cause serious injuries.
COLD WEATHER
OPERATION
Under certain weather conditions (temperatures below
40°F [4°C] combined with high humidity), your
Craftsman generator may experience icing of the
carburetor and/or the crankcase breather system. To
reduce this problem, you need to perform the following:
Make sure generator has clean, fresh fuel.
Open fuel tank valve (turn valve to open position).
Use SAE 5W-30 oil (synthetic preferred, see page 5).
Check oil level daily or after every eight (8) hours
of operation.
Change oil every 24 hours of operation.
Shelter unit from the elements.
In an emergency, use the original shipping carton as a
temporary shelter:
Cut off all carton flaps.
Cut out one of the long sides of the carton to
expose muffler side of unit as shown. Ensure a
minimum of two feet clearance between open side
of carton and nearest object.
Wind
Muffler side exposed. Your unit may differ in
appearance from that shown above.
Cut appropriate slots to access receptacles of unit.
Start unit, then place carton over it.
NOTE: Remove carton when temperature
is above
40°F [4°C].
For a more permanent shelter, build a structure that
will enclose three sides and the top of the generator.
Make sure entire muffler-side of generator is
exposed, as shown.
Ensure a minimum of two feet clearance between
open side of structure and nearest object.
Face exposed end away from wind and elements.
Structure should hold enough heat created by the
generator to prevent icing problem.
_
ARNING!
Engines give off carbon monoxide,
an odorless, colorless, poison gas. Breathing
carbon monoxide can cause nausea, fainting or
death.
Start and run engine outdoors.
Do Not start or run engine in enclosed area, even
if doors or windows are open.
Do Not enclose generator any more than shown.
Remove shelter when temperatures are above
40°F [4°C].
Turn engine OFF and let cool two (2) minutes
before refueling.