Download Print this page

Craftsman 580.326301 Owner's Manual

6300 watt electric start ac generator

Advertisement

Available languages

Available languages

Quick Links

Manual
GENERATOR
CUSTOMER
HELPUNE
HOURS:
Non. - Fri. 8 a.m. to 5 p.m. (CT)
1.11
PRECAUCI6N
Antes de utilizar
e]producto, leaeste
manual y siga todas las Reglas de
Seguridad e Instrucciones de Uso.
Sears,
Roebuck
and Co.,
Hoffman
Estates,
_L 60179
U.S.A.
Visit our Craftsman
website:
www.craftsman.com
Part No. 196822GS Draft 4 (11/08/2005)
o Safety
o Assembly
o Operation
o Maintenance
o Parts
o EspaSol

Advertisement

loading

Summary of Contents for Craftsman 580.326301

  • Page 1 Parts Antes de utilizar e]producto, leaeste manual y siga todas las Reglas de o EspaSol Seguridad e Instrucciones de Uso. Sears, Roebuck and Co., Hoffman Estates, _L 60179 U.S.A. Visit our Craftsman website: www.craftsman.com Part No. 196822GS Draft 4 (11/08/2005)
  • Page 2 WARRANTY ........TROUBLESHOOTING ......SAFETY RULES ....... SCHEMATIC DIAGRAM ......FEATURES AND CONTROLS ...... WIRING DIAGRAM ......ASSEMBLY ........REPLACEMENT PARTS ....... 20°28 OPERATION ......... 8-11 NOTES ........SPECIFICATIONS ....... EMISSION CONTROL WARRANTY ....30o31 MAINTENANCE ......13o15 ESPA!_OL ........32o51 STORAGE ........
  • Page 3 This is the safety alert symbol. It is used to alert you to potentiam personal inju_' hazards. Obey all safety messages that foltow this symbol to avoid possible injury or death. WARNtNG ii_!_l;ij Read this manuat carefully and become familiar with your generator. Know its applications, its limitations,...
  • Page 4 WARNING WARNING WHEN ADDING OR DRAINmNG FUEL WHEN ADJUSTmNG OR MAKING REPAIRS TO YOUR Turn generator OFF and let it cool at least 2 minutes GENERATOR before removing fuel cap. Loosen cap slowly to relieve * Disconnect the spark plug wire from the spark plug and pressure in tank.
  • Page 5 KNOW YOUR GENERATOR _Read the owner's manua{ and safety rules before operating your generator, ..Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. Fuel Valve Rocker Switch (on engine shroud) (not shown)_./)
  • Page 6 ASSEMBLY • Pliers • Safety glasses Your Craftsman generator requires some assembly and is ready for use only after it has been properly Install the Wheel Kit as Follows: serviced with the recommended oil and fuel. Tip generator so that engine end is up.
  • Page 7 12.Check t hatallfasteners aretight a ndtiresareinflated Add Fuem tovalue marked o ntireorwithin 15and40psi. NOTE: This gasoline engine is certified to operate on gasoline. Exhaust Emission Control System: EM Check Battery / Attach Negative Battery (Engine Modifications). Wire WARNING The sealed battery on the generator is fully charged and pre-installed except for the negative (black) battery cable.
  • Page 8 HOW TO USE YOUR GENERATOR Generator Location if you have any problems operating your generator, Generator Clearance please call the generator helpline at 1=800-222-3136. WARNING System Ground The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.
  • Page 9 TO START THE ENGINE Slowly move choke lever to "Run" position. If engine falters, move choke lever to "Half" choke IMPORTANT: AM_ays unplug the battery float charger position until engine runs smoothly, and then to before starting the generator. "Run" position. Disconnect all electrical loads from the generator.
  • Page 10 TO STOP THE ENGINE 120/240 Volt AC, 30 Amp Receptacle This is a full capacity receptacle; it can supply the Unplug all electrical loads from generator panel generator's full rated output from this sole outlet. The receptacles. NEVER start or stop engine with outlet is protected by two 30 Amp push-to-reset electrical devices plugged in and turned on.
  • Page 11 DON'T OVERLOAD GENERATOR Plug in and turn on the next load. Again, permit the generator to stabilize. Capacity Repeat steps 4 and 5 for each additional load. You must make sure your generator can supply NEVER add more loads than the generator capacity. enough rated (running) and surge (starting) watts for Take special care to consider surge loads in generator the items you will power at the same time.
  • Page 12 ENGINE TECHNICAL INFORMATION PRODUCT SPECIFICATIONS This is a single cylinder, overhead valve(OHV), air Generator Specifications cooled engine, it is a low emissions engine. Wattage ....6300 Watts (6.3 kW) in the State of California, Model Series 210000 Starting Wattage ..... 9100 Watts (9.1 kW) engines are certified by the California Air Resources Rated AC Voltage ....
  • Page 13 OWNER'S RESPONSIBILITIES Follow the hourly or calendar intervals, whichever occurs first. More frequent service is rec uired when operating in adverse conditions noted below. MABNTENANCE SCHEDULE FtLL tN DATES AS YOU SERVICE DATES COMPLETE REGULAR SERVICE SERVICE DATES Every 100 Before Every 25 Hours Every 50 Hours...
  • Page 14 ENGINE MAINTENANCE Changing Engine OH Change the oil after the first 5 hours of operation. WARNING Change oil every 50 hours thereafter. If you are using your generator under extremely dirty or dusty conditions, or in extremely hot weather, change the oil more often. CAUTION WHEN ADJUSTING...
  • Page 15 Service Air Cleaner if you use your generator on any forest-covered, brush- covered, or grass-covered unimproved land, it must Your engine will not run properly and may be have a spark arrester. The spark arrester must be damaged if you run it using a dirty air cleaner. Clean maintained in good condition by the owner/operator.
  • Page 16 Change OH While engine is still warm, drain oil from crankcase. Thegenerator shouldbestarted atleastonceevery Refill with recommended grade. sevendaysandallowed torunat least30minutes. I f thiscannot b edoneandyoumuststoretheunitfor OHCylinder Sore morethan30days,usethefollowing information a s a guideto prepare itforstorage. • Remove spark plug and pour about 1 ounce (30ml) of clean engine oil into the cylinder.
  • Page 17 Prob{em Correction C_use One of the circuit breakers is Reset circuit breaker. open. Poor connection or defective Check and repair. Engine Bsrunning, but no AC cord set. output is available. Connected device is bad. Connect another device that is in good condition. Fault in generator.
  • Page 18 CRAFTSMAN B300 Watt AC Generator 580.326301 B-SRAS$ SCREW S-SILVER SCREW GR OREEN SCREW POWER POWER 120V _-_o 120/248V 600V BATTERY DIODE ii I _IOAT STARTER CHAR@!!KR INPUT ELECTRIC START SW]TCH...
  • Page 19 CRAFTSMAN 6300 Watt AC Generator 580.326301 FLOAT IBVDC CHARGER [NPUr NEITE: PBSITIVE BRUSH CLUSEST BEARING ELECTRIC START SWITCH STATOR GROUND SUPPLIED BATTERY...
  • Page 20 CRAFTSMAN 6300 Watt AC Generator 580.326301 Main Unit m E×p_oded View DETAIL OF JACK ASSEMBLY COAXAL DEIAiL BATTERY TRAY DETAIl OF ELECTRIC S;AR SWI/CI! STARTER IERMINAI BAiTERY...
  • Page 21 CRAFTSMAN 6300 Watt AC Generator 580.326301 Main Unit m Parts List Item Part # Part # Description Item Description M197464GS CRADLE B4135GS PIN, with Lanyard 194150GS 77395GS KIT, Mount, Vibration, 45 ° NUT, M6 Flange Lock 190220GS 195373GS HOUSING, Engine Adapter...
  • Page 22 CRAFTSMAN 6300 Watt AC Generator 580.326301 Contro{ Pane{ m Exp{oded View and Parts List Item Part # Description 195112GS KIT, Control Panel Lid 191450GS CONTROL PANEL, Compact 68759GS OUTLET, 120V, 20Amp, Duplex NUT, Palnut, 5/32 84198GS CAP, Circuit Breaker 75207AGS...
  • Page 23 CRAFTSMAN 6300 Watt AC Generator 580.326301 Whee{ Kit m Exp{oded View and Parts List ..9 Item Part # Description VVASHER, 5/8 B4966GS WHEEL 191267GGS AXLE, 5/8" x 23.62" 191265GS EzR]NG, 5/8 HHCS, M8 z 1.25 x 20 B187101GS LEG, Support...
  • Page 24 CRAFTSMAN 6300 Watt AC Generator 580.326301 Alternator m E×p[oded View and Parts List Part # Item Description 186059GS ADAPTER, Mounting, Alternator 191876GS ROTOR 194006AGS STATOR 186060GS RBC, (with OzRing, p/n 189197GS) 86308HGS HHCS, M6 z 1.0 x 140 SEMS 66386GS...
  • Page 25 ENGINE, 11 HP, Briggs and Stratton, 210415 - Exploded View 718A 22 _:_ 27 o...
  • Page 26 ENGINE, 11 HP, Briggs and Stratton, 210415 - Exploded View 1026_ 798_ 4s _ 1100 8 564A 564 _ 1171 GASKET SET CARBURETOR 137_ 633 @ 1 _L_ 163_ 633 @ 121 CARBURETOR OVERHAUL 117 ® 163_ 633@...
  • Page 27 ENGINE, _1 HP, Briggs and Stratton, 210415 - Exploded View 579 _ 310_% 1070 332_ ENGINE GASKET 8680 689 % 5iA_ i21i i095 VALVE GASKET i2i0 65 _®...
  • Page 28 ENGINE, HP, Briggs and Stratton, 210415 - Parts List item PaR # Description item Part # Description 697702 Cylinder Assembly 697240 Shield-Cylinder 697719 Kit-Bushing/Seal (Magneto Side) 691660 Screw (Cylinder Shield) 391086 Motor-Starter Seal-Oil (Magneto Side) 695479 697233 Head-Cylinder 690323 Bolt (Starter Motor) 697690 Brush Set Gasket-Cylinder...
  • Page 30 Sears, Roebuck and Co., U.S.A. (Sears), the California Air Resources Board (CARE}) and the United States Environmenta_ Protection Agency (U.S.EPA) Emissions Contro_ System Warranty Statement (Owner's Defect Warranty Rights and Obligations) The California Air Resources Board (CARB), U.S. EPA and Fuel Metering System Sears...
  • Page 31 Emissions Durability Period and Air index Emissions Compliance Period On Engine Information On Your Engine Emissions Labe_ Emissions Compliance Labe_ Engines that are certified to meet the California After July 1,2000 certain Sears engines will be certified Resources Board (CARB) Tier 2 Emission Standards must...
  • Page 32 ......38o41 PARTES/SERVICIO ....ULTJMA PAGINA ESPECIFICACIONES DEL PRODUCTO ..... GARANTIA LIMiTADA DE GENERADOR PORTATtLE CRAFTSMAN SEARS garantiza al comprador original que el altemador y el motor para su generador portati! estaran Iibres de defectos los materiales o la mano...
  • Page 33 Este es e[ simbo[o de a[erta de seguridad. Es usado para indicar[e situaciones con pe[igros potencia[es lesion para e[ persona[. Siga [as instrucciones de todos los mensajes de seguridad que aparecen despues este simbo[o para evitar posib[es [esiones o muerte. Lea este man°a, de maoera co,dadosa...
  • Page 34 ADVERTENCIA CUANDO AJUSTE O HAGA REPARACIONES A SU GENERADOR • Siempre desconecte et atambre de ta bujia y col6quelo donde Cuando use un generador como poder de energia auxiliar, notifique a ta compa_ia de utilidades. Use et equipo de transferencia no pueda entrar en contacto con la bujia.
  • Page 35 CONOZCA SU GENERADOR [_ii! _ Lea este manuaJ del propietario y las reglas de segurJdad antes de operar su generador. Compare las iJustraciones con su generador para famiJiadzarse con la ubicaci6n de los diferentes controles y ajustes. Conserve este manuaJ para referencias futuras. Interruptor Balanc[n Tanque...
  • Page 36 Llave de 1/2" 6 13 mm Llave de cubo de 1/2" 6 13 mm Su generador requiere de ciertos procedimientos de montaje y Alicates solo estara listo para ser utilizado despues de haberle Gafas de seguridad suministrado servicio con el combustible y aceite recomendados.
  • Page 37 10. Conecte e! otro lado de la pierna de apoyo con un Agregue Gasolina 20 mm torni!lo de la tapa y nuez de cerradura. NOTA: Este motor esta certificado para funcionar 11. Vuelva a colocar e! generador en la posicion normal gasolina.
  • Page 38 COMO USAR SU GENERADOR Ubicaci6n del Generador Si tiene problemas operando su generador, por favor Ilame Espacio Libre A[rededor de[ Generador a la linea de ayuda para generadores a! 1o800o222o3136. ADVERTENCJA Tierra de_ Sistema El generador dispone de una conexion a tierra del sistema que conecta los componentes...
  • Page 39 PARA ENCENDER EL MOTOR Co!oque la palanca de retroceso en la posici6n "Run" (marcha). Si el motor vacila, mueva la palanca IMPORTANTE: Desenchufe siempre el cargador retroceso hasta la posicion media "Half" hasta que e! flotaci6n de la bateria antes de arrancar el generador.
  • Page 40 PARADO DEL MOTOR Tomacorriente de 1201240 Vo_tios AC, 30 Amperios Desconecte todas las cargas el6ctricas de la unidad. NUNCA arranque o detenga el motor con dispositivos Este es un tomacorriente de capacidad total, Io que significa electricos conectados a 61 y encendidos, que usted puede tomar...
  • Page 41 NO SOBRECARGUE GENERADOR Conecte y encienda la proxima carga. De nuevo, permita que el generador se estabilice. Capacidad Repita los pasos 4 y 5 para cada carga adicional Usted debe asegurarse que su generador puede proveer usted tenga. suficiente vataje calificado (cuando este funcionando) y de...
  • Page 42 INFORMACION Tg:CNICA SOBRE EL ESPECIFtCACtONES MOTOR PRODUCTO El motor es de uno cilindros, de valvulas en cabeza (OHV), Especificaciones del Generador refrigerado por aire y de baja emisi6n. Vataje ......6,300 vatios (6.3 kW) En e! Estado de California, los motores de la serie 210000 Vataje que Empieza...
  • Page 43 RESPONSIBILADES DEL CLIENTE Siga los intervalos horarios o de calendario,_ue ocurra primero. Se requiere de servicio con mayor frecuencia cuando opere la unidad en las condiciones adversas descritas a continuaci6n. CALENDARIO DE MANTENIMIENTO INTERVALO DE OPERACION POR HORA ANOTE LAS FECHAS CONFORME CUMPLA CON EL SERVICIO NORMAL FECHAS...
  • Page 44 Mantenimiento de [a Bater[a Comprobaci6n de[ hive[ de aceite Compruebe el nive! de aceite antes de cada uso o cada 5 De otra manera que chorrea un poco cargar, descrito horas de funcionamiento, como minimo. Rellene si es otra parte, la conservaci6n ningOn otro se requiere...
  • Page 45 LimpelReemp_ace _a Bujia Proporcione Servicio a_ Depurador de Aire Cambie la bujia cada 100 horas de operacion o una vez al Su motor no funcionara correctamente y podria resultar also, Io que suceda primero. Esto ayudara a su motor da_ado si !o hace funcionar con un depurador de aire sucio.
  • Page 46 Limpie _a PantaHa Apagachispas Limpie e inspeccione e[ apagachispas de Ja siguiente manera: El silenciador del escape de! motor posee una pantalla Para retirar la protecci6n del silenciador, retire los apagachispas. Inspeccione y limpie la pantalla cada 100 horas cuatro tornillos que conectan la protecci6n...
  • Page 47 GENERALIDADES Cambio de Aceite Con el motor todavia caliente, drene e! aceite de la caja del El generador deber& ser encendido al menos una vez cada cig_eSaJ. Vuelva a !lenarlo con el grado de aceite siete dias y debera dejarlo funcionar al menos durante...
  • Page 48 Problemo Accion Causa El interruptor automatico de circuito Reposicione el interruptor, esta abierto, Conexi6n real o defectuosa Revise y repare, juego de cables. E! motor est_ funcionando pero e×iste salida de A¢ disponsible. El dispositivo conectado esta Conecte otro dispositivo que este da_ado, buenas...
  • Page 50 Sears, Roebuck and Co., U.S.A. (Sears), California Resources Board (Consejo de Recursos sobre e! Aire California, CARB, por sus sigJas en ingles) y United States Environmental Protection Agency (Agencia de Protecci6n Ambienta[ de EE.UU., EPA, pot sus sig[as en ingles). Declaraci6n de garantia del sistema...
  • Page 51 Jnformaci6n Sobre el Periodo Periodo de Cump_imiento de _a Normativa Durabilidad de las Emisiones y e_ indice de Emisiones en ia Etiqueta de Aire en _a Etiqueta de Emisiones CumpHmiento de Emisiones del Motor Motor Desde el 1 de julio de 2000, algunos motores Sears...
  • Page 52 Your Home For repair-in your home-of alJ major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter made it, no matter sold For,the replacement parts, accessories owner s manuals that you need to do-it-yourself. For Sears professional installation of home appliances and items like garage...