Electrical Specifications; Environmental Requirements; A.3 Electrical Specifications; A.4 Environmental Requirements - Enterasys 2H252-25R Installation & User Manual

Enterasys networks installation user's guide smartswitch 2200 2h252-25r
Hide thumbs Also See for 2H252-25R:
Table of Contents

Advertisement

Electrical Specifications

A.3
ELECTRICAL SPECIFICATIONS
Line Input Range, Volts (V)
Input Current, Amperes (A)
Frequency, Hertz (Hz)
Input Power, Volt Amperes (VA)
A.4

ENVIRONMENTAL REQUIREMENTS

Operating Temperature:
Storage Temperature:
Operating Relative Humidity:
A.5

INPUT/OUTPUT PORTS

Ports 1 through 24:
Interface Slot:
A-2
Specifications
100–125 Vac
2.3 A
50/60 Hz
250 VA
5°C to 40°C (41°F to 104°F)
-30°C to 73°C (-22°F to 164°F)
5% to 90% (non-condensing)
Fast Ethernet 10/100 Mbps (10BASE-T and
100BASE-TX compliant) with RJ45 type
connectors.
Slot accepts optional High Speed Interface Module
(HSIM) or Very High Speed Interface Module
(VHSIM) to provide a variety of cabling
connections.
200–240 Vac
1.2 A
50/60 Hz
250 VA