Managing The Hub; Using Device Find Source Address - Enterasys FN 100 User Manual

Netsight element manager
Hide thumbs Also See for FN 100:
Table of Contents

Advertisement

Managing the Hub

In addition to the performance and configuration information described in the
preceding sections, the Chassis View also provides you with the tools available to
configure your device and keep it operating properly. Hub management for the
FN100 is comprised of locating source addresses, viewing interface statistics and
CSMACD statistics, as well as administratively enabling and disabling the ports.

Using Device Find Source Address

When you select the Device Find Source Address option, the device's 802.1d
Filtering database is searched for the specified MAC address. If it is found, the
Component field will display the value "Bridge" indicating that the address was
found on a bridging interface, and the Port Instance field will display the index
number assigned to the bridge port on which the address was located.
You may receive an error message stating "Can't Display Source Address" if a Port
Instance of "0" or "0.0" is reported. This value indicates that the MAC address is
NOTE
communicating through the backplane instead of through a front panel interface.
To open the Device Find Source Address window:
1. Click on Device in the Chassis View menu bar.
2. Click on Device Find Source Address. The Device Find Source Address
Managing the Hub
Figure 2-5. Port Description Windows
window, as shown in
Figure
2-6, opens.
The FN100 Chassis View
2-11

Advertisement

Table of Contents
loading

Table of Contents