3‐3 shows connecting a twisted pair segment to the 2G4082‐25 module. It is assumed that 
the chassis power is turned on to provide power to the module. Refer to Figure
follows:
1.
Ensure that the device connected to the other end of the segment is powered ON.
2.
Connect the twisted pair segment to the module by inserting the RJ45 connector on the 
twisted pair segment into the appropriate RJ45 port connector. 
Figure 3-3

Connecting a Twisted Pair Segment to the DFE-Platinum Module

1 RJ45 connector
3.
Verify that a link exists by checking that the port RX (Receive) LED is ON (flashing amber, 
blinking green, or solid green). If the RX LED is OFF and the TX (Transmit) LED is not 
blinking amber, perform the following steps until it is on:
a.
To view the receive and transmit activity on a group of segments, press the GROUP 
SELECT button (see Figure
time the GROUP SELECT button is pressed, the GROUP LED lights up in sequence, 
indicating which Group is selected. The receive and transmit activity for that group of 
segments is then indicated by the RX and TX LEDs for each segment.
b. Verify that the cabling being used is Category 5 UTP with an impedance between 85 and 
111 ohms. For the port to operate at 100 or 1000 Mbps, Category 5 cabling must be used 
and installed properly.
c.
Verify that the device at the other end of the twisted pair segment is on and properly 
connected to the segment.
d. Verify that the RJ45 connectors on the twisted pair segment have the proper pinouts and 
check the cable for continuity. Typically, a crossover cable is used between hub devices. A 
straight‐through cable is used to connect between switches or hub devices and an end 
user (computer). Refer to Figure 3‐4 and Figure
to Figure 3‐6 and Figure
Á
À
2 RJ45 port connector (port 1)
3‐3) to step to the group of interest (Groups 1 and 2). Each 
3‐7 for eight‐wire RJ45 connections.
Connecting to the Network
3‐3 and proceed as 
Â
3 GROUP SELECT button
3‐5 for four‐wire RJ45 connections. Refer 
Matrix DFE-Platinum Series Installation Guide 3-7