Asus TS700-E6 RS8 User Manual page 65

Pedestal/5u rackmount server
Table of Contents

Advertisement

7.
CPU, front and rear fan connectors
(4-pin CPU_FAN1, CPU_FAN2, FRNT_FAN1, FRNT_FAN2, FRNT_FAN3,
FRNT_FAN4, REAR_FAN1, REAR_FAN2)
The fan connectors support cooling fans of 350 mA–740 mA (8.88 W max.)
or a total of 3.15 A–6.66 A (53.28 W max.) at +12V. Connect the fan cables to
the fan connectors on the motherboard, ensuring that the black wire of each
cable matches the ground pin of the connector.
DO NOT forget to connect the fan cables to the fan connectors. Insufficient
air flow inside the system may damage the motherboard components.
These are not jumpers! DO NOT place jumper caps on the fan connectors!
All fans feature the ASUS Smart Fan technology.
8.
LPC debug card connector (14-1 pin LPC1)
This is a low pin count interface used to plug in the LPC debug card.
ASUS TS700-E6/RS8
4-13

Advertisement