Table Of Contents; Specifications; Read Carefully; Before Installing - COZY VC501A Installation And Operation Instructions Manual

Gas-fired vented room heater
Table of Contents

Advertisement

TABLE OF CONTENTS
SPECIFICATIONS............................
2
INTRODUCTION.............................
3
VENTING.......................................
3,4
GAS StJPPLY..................................
5
LOCATION & SPECIAL PRECAUIIONS
5
COMBUSTION & VENTILATION AIR ....
6
CLEARANCES................................
7
DRAFTD1VERTER..........................
7
I_ORKNOB .................................
7
PILOTADJUSTMENT ......................
8
RADIANTS & GLASS PANELS...........
8
BURNER ORIFICE & ORIFICE CHART.......... 8
PROPER BURNER FLAME ..........................
9
MAINTENANCE .....................................
9
LIGHTING INSTRUCTIONS .......................
10
TROUBLE SHOOTING CHART ............
11,12
BLOWER INSTRUCTIONS ..................
13
PARTSDRAWING.............................
14
PARTSPRICE LIST............................
15
WARRANTY....................................
17
READ CAREFULLY
BEFORE INSTALLING
UNIT
These installation
instructions
are a general guide and do not supersede
applicable
local codes and ordinances.
Before
planning
or making the installation
be sure it complies
with all phases of the local heating code.
(Or, in the absence of
local codes, with the latest edition of National
Fuel Gas Code, ANSI.Z223.1,
or CAN1-B 149).
The appliance,
when installed, must be electrically
grounded
in accordance
with local codes, or in the absence of local
codes, with the latest edition of National Electrical
Code ANSI/NFPA
70, or Canadian
Electrical
Code CSA-C22.1.
All of the ANSI and NFPA standards
referred
to in these installation
instructions
are the ones that were applicable
at
the time the design of this appliance
was certified.
The ANSI standards are available from the American Gas Association,
1515 Wilson Blvd., Arlington,
VA. 22209.
The NFPA standards
are available
from the national
Fire Protection Association,
60 Batterymarch
Street, Boston,
Massachusetts
02110.
Canadian
standards are available
from International
Approval
Services,
178 Rexdale
Boulevard,
Etobicoke,
Ontario,
Canada M9W 1R3.
The design of this appliance
was certified
to comply with ANSI Z21.11.1
vented room heaters and CAN1-2.1-M86.
Installer
must leave these instructions
with the consumer,
have them complete,
and return the warranty
card.
ROOM HEATER SPECIFICATIONS
Your room heater comes packed in a single carton. Before installation, check the rating plate to verify that the Model Number is
correct and that the room heater is equipped t\_r the type gas you intend to use.
SPECIFICATIONS
TYPE
CONTROL
GAS
MODEL
NUMBERS
CLOSED FRONT
THERMOSTAT BULB NATURAL
VC201A
VC351A
VC501A
VC701A
CLOSED FRONT
THERMOSTAT BULB L.P
VC202A
VC352A
VC502A
VC702A
RADIANTFRON1
THERMOSTAT BULB NATURAL
N/A
VCR351A
VCR501A
VCR701A
RADIANTFRON1
THERMOSTAT BULB L.R
N/A
VCR352A
VCR502A
VCRT02A
HEIGHT
20"
26"
26"
30"
WIDTH
24"
30"
30"
36"
DEPTH
15-1/4"
15-1/4"
19-1/4"
19-1/4"
INPUT (BTU/HR.)
20,000
35,000
50,000
70,000
GAS INLET/OUTLET SIZE
VENT SIZE
CENTER OF VENT TO FLOOR
NUMBER OF RADIANTS ("VCR" SERIES)
NUMBER OF RADIANT GLASS _"VCR" SE___.ES_
APPROX. SHIPPING WEIGHT ("VC" SERIES)
APPROX. SHIPPING WEIGHT ("VCR" SERIES)
*OPTIONAL BLOWER MODEL
1/2X3/8"
3"
16-1/2"
N/A
N/A
55 LBS.
N/A
N/A
1/2X3/8"
4"
21-1/2"
5
2
84 LBS.
96 LBS.
CHB-3
1/2X3/8"
4"
21-1/2"
5
2
ll2LBS.
124 LBS.
CHB-3
1/2X3/8"
5"
25-1/2"
5
2
138 LBS.
150 LBS.
CHB-3
*Blowers also available factory mounted on 50M Btu units. All 70M Btu units come with blower mounted only.