Cr_Syslist Command - Sanyo PLC-XC50 - 2600 Lumens Manual

Expand serial command functional specifications
Hide thumbs Also See for PLC-XC50 - 2600 Lumens:
Table of Contents

Advertisement

PLC-XC50/55 Expand Serial Command Functional Specifications
Unacceptable
9.7.7

CR_SYSLIST Command

Command
"CR_SYSLIST"[CR]
Details
Get selectable System titles
Acceptable
Response
%1
Unacceptable
"AUTO" --------------- Auto is selected
"NTSC" --------------- NTSC is selected
"NTSC443" ---------- NTSC4.43 is selected
"PAL" ------------------ PAL is selected
Input is
"SECAM" ------------- SECAM is selected
Video,
S-Video
"PALÿ M" ------------- PAL-M is selected
"PALÿ N" ------------- AL-N is selected
Projector returns selected System status regardless of the
signal input.
""Error Code"[CR]
"000_%1_%2_..._%x" [CR]
- When Input is PC-Analog
"XGA1" ------------ XGA1is selectable
"1080I " ----------- 1080i is selectable
Projector does not return Auto,Mode1-5
When there is no signal, it returns Error Code "101"
-When Input is PC-Digitalÿ AV-HDCP
"D-XGA" ----------- D -XGA is selectable
"D-720P" ---------- D -720P is selectable
When there is no signal, it returns Error Code "101"
-When Input is Y,Pb/Cb,Pr/Cr
Returns all the System titles on Menu including Auto
"AUTO" ------------ Auto is selectable
"1080I" ------------ 1080i is selectable
"1035I" ------------ 1035i is selectable
ÿ
ÿ
"575I" ------------ 575i is selectable
"480I" ------------ 480i is selectable
Projector does not return Error Code "101" even if there is no
signal.
-When Input is Video, S-Video
Returns all the System titles on Menu including Auto
"AUTO" ---------Auto is selectable
"PAL" ------------ PAL is selectable
"SECAM" ------ SECAM is selectable
ÿ
ÿ
"PAL-N" --------- SECAM is selectable
Projector does not return Error Code "101" even if there is no
signal.
""Error Code"[CR]
51/67